ASTM F1875-98 PDF

ASTM F1875-98 PDF

Name:
ASTM F1875-98 PDF

Published Date:
04/10/1998

Status:
Active

Description:

Standard Practice for Fretting Corrosion Testing of Modular Implant Interfaces: Hip Femoral Head-bore and Cone Taper Interface

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
astm-f1875-98_101267

Choose Document Language:
17.40 €
Need Help?

1.1 This practice describes the testing, analytical, and characterization methods for evaluating the mechanical stability of the bore and cone interface of the head and stem junction of modular hip implants subjected to cyclic loading by measurements of fretting corrosion. (1-5) Two test methods described are as follows:

1.1.1 Method I-The primary purpose of this method is to provide a uniform set of guidelines for long-term testing to determine the amount of damage by measurement of the production of corrosion products and particulate debris from fretting and fretting corrosion. Damage also is assessed by characterization of the damage to the bore and cone surfaces. (4,5)

1.1.2 Methods II-This method provides for short-term electrochemical evaluation of the fretting corrosion of the modular interface. It is not the intent of this method to produce damage nor particulate debris but rather to provide a rapid method for qualitative assessment of design changes which do not include material changes. (1-4)

1.2 This practice does not provide for judgment or prediction of in vivo implant performance, but rather, provides for a uniform set of guidelines for evaluating relative differences in performance between differing implant designs, constructs, or materials with performance defined in the context of the amount of fretting and fretting corrosion. Also, this practice should permit direct comparison of fretting corrosion data between independent research groups, and thus, provide for building of a data base on modular implant performance.

1.3 This practice provides for comparative testing of manufactured hip femoral heads and stems and for coupon type specimen testing where the male taper portion of the modular junction does not include the entire hip implant, with the taper portion of the coupon identical in design, manufacturing, and materials to the taper of the final hip implant. (4,5)

1.4 Method I of this practice has been provided in a manner to permit simultaneous evaluation of the fatigue strength of a femoral hip stem (in accordance with Practice F1440) and the mechanical stability and debris generated by fretting and fretting corrosion of the modular interface.

1.5 The general concepts and methodologies described in this practice could be applied to the study of other modular interfaces in total joint prostheses.

1.6 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 88 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 6
Published : 04/10/1998

History

ASTM F1875-98(2022)
Published Date: 10/01/2022
Standard Practice for Fretting Corrosion Testing of Modular Implant Interfaces: Hip Femoral Head-Bore and Cone Taper Interface
17.10 €
ASTM F1875-98(2014)
Published Date: 10/01/2014
Standard Practice for Fretting Corrosion Testing of Modular Implant Interfaces: Hip Femoral Head-Bore and Cone Taper Interface
20.40 €
ASTM F1875-98(2009)
Published Date: 12/01/2009
Standard Practice for Fretting Corrosion Testing of Modular Implant Interfaces: Hip Femoral Head-bore and Cone Taper Interface
17.40 €
ASTM F1875-98(2004)
Published Date: 08/01/2004
Standard Practice for Fretting Corrosion Testing of Modular Implant Interfaces: Hip Femoral Head-bore and Cone Taper Interface
17.40 €
ASTM F1875-98
Published Date: 04/10/1998
Standard Practice for Fretting Corrosion Testing of Modular Implant Interfaces: Hip Femoral Head-bore and Cone Taper Interface
17.40 €

Related products

ASTM F1246-91(2005)
Published Date: 12/01/2005
Standard Specification for Electrically Powered Home Care Ventilators, Part 1-Positive-Pressure Ventilators and Ventilator Circuits (Withdrawn 2014)
19.50 €
ASTM F2118-14(2020)
Published Date: 09/01/2020
Standard Test Method for Constant Amplitude of Force Controlled Fatigue Testing of Acrylic Bone Cement Materials
16.80 €
ASTM F2052-21
Published Date: 10/01/2021
Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment
16.20 €
ASTM F1611-20(2024)
Published Date: 10/01/2024
Standard Specification for Intramedullary Reamers
16.50 €

Best-Selling Products

BS ISO/TR 10064-1:1992
Published Date: 11/30/2006
Code of inspection practice-Inspection of corresponding flanks of gear teeth
110.49 €
BS ISO/TR 10064-2:1996
Published Date: 12/29/2006
Code of inspection practice-Inspection related to radial composite deviations, runout, tooth thickness and backlash
92.96 €
BS ISO/TR 10064-3:1996
Published Date: 11/30/2006
Code of inspection practice-Recommendations relative to gear blanks, shaft centre distance and parallelism of axes
57.15 €
BS ISO/TR 10064-4:1998
Published Date: 11/30/2006
Code of inspection practice-Recommendations relative to surface texture and tooth contact pattern checking
79.25 €
BS ISO/TR 10193:1989
Published Date: 01/15/1996
Round general use light gauge metal containers. Nominal filling volumes and nominal diameters
57.15 €
BS ISO/TR 10194:1989
Published Date: 01/15/1996
Non-round general use light gauge metal containers. Nominal filling volumes and nominal cross-sections
57.15 €