Description:

Standard Practice for Reprocessing of Reusable, Heat-Stable Endoscopic Accessory Instruments (EAI) Used with Flexible Endoscopes (Withdrawn 2016)

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$17.4
Need Help?

1.1 This practice covers reusable, heat-stable endoscopic accessory instruments (EAI) designed to be inserted into flexible endoscopes and clearly defined in the user instructions as devices intended for reuse among patients. The EAIs covered by this practice may or may not have lumens or loosely joined surfaces, may or may not have access ports for flushing, and may or may not be capable of being completely disassembled prior to reprocessing.

1.2 This practice is not intended to be applied to the reprocessing of single-use, disposable EAIs specifically designed and labeled as such by their manufacturers.

1.3 This practice is not intended to address reprocessing of heat-sensitive EAIs, for example, those not capable of withstanding heat sterilization. Reprocessing of each heat-sensitive EAI must be considered on an individual basis according to specific instructions from the manufacturers of the EAI and the low-temperature sterilization device.

1.4 This practice is intended to complement, not replace, the instructions provided by product manufacturers. EAI manufacturers should provide properly validated instruction and labeling necessary for users to understand the basic design, specifications, nomenclature, and components of specific accessories and to properly inspect, prepare, use, reprocess, and store these instruments.

1.5 Endoscopic technique and the medical aspects of endoscopy are not covered in this practice.

1.6 This practice details the basic steps necessary to reprocess a heat-stable EAI and render it patient-ready.

1.7 A patient-ready EAI is one that has been thoroughly cleaned using a validated cleaning procedure, rinsed with water to remove residual detergent, lubricated (if necessary) and drained to remove excess lubricant, dried, packaged, heat sterilized and stored to prevent from being compromised sterility before use.

1.8 This practice describes only manual reprocessing and does not address cleaning of an EAI by an automated reprocessing device.

1.9 To ensure the proper adherence to this practice, reprocessing personnel should meet certain requirements as specified in 5.5 to 5.7.

1.10 This practice does not address the steps necessary for the reprocessing of flexible endoscopes (see Practice F 1518).

1.11 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 79 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 6
Published : 12/01/2007

History

ASTM F1992-99(2007)
Published Date: 12/01/2007
Standard Practice for Reprocessing of Reusable, Heat-Stable Endoscopic Accessory Instruments (EAI) Used with Flexible Endoscopes (Withdrawn 2016)
$17.4
ASTM F1992-99
Published Date: 10/10/1999
Standard Practice for Reprocessing of Reusable, Heat-Stable Endoscopic Accessory Instruments (EAI) Used with Flexible Endoscopes
$17.4

Related products

ASTM F1855-00(2019)
Published Date: 12/01/2019
Standard Specification for Polyoxymethylene (Acetal) for Medical Applications
$13.2
ASTM F719-20e1
Published Date: 04/01/2020
Standard Practice for Testing Materials in Rabbits for Primary Skin Irritation
$13.8
ASTM F1904-23
Published Date: 04/01/2023
Standard Guide for Testing the Biological Responses to Medical Device Particulate Debris and Degradation Products in vivo
$17.1
ASTM F136-13(2021)e1
Published Date: 11/01/2013
Standard Specification for Wrought Titanium-6Aluminum-4Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications (UNS R56401)
$15.6

Best-Selling Products

ASHRAE 100-1995 Addendum b
Published Date: 1997
Addendum b - Energy Conservation in Existing Buildings
Free Download
ASHRAE 100-1995
Published Date: 1995
Standard 100-1995 -- Energy Conservation in Existing Buildings (ANSI Approved/IESNA cosponsored)
$11.1
ASHRAE 100-2006
Published Date: 2006
Standard 100-2006 -- Energy Conservation in Existing Buildings (ANSI/IES Approved)
$11.7
ASHRAE 100-2015 Addenda a
Published Date: 2017
Addenda a to Standard 100-2015 -- Energy Efficiency in Existing Buildings (ANSI Approved/IES Co-sponsored)
Free Download
ASHRAE 100-2015 Addenda b
Published Date: 2017
Addenda b to Standard 100-2015 -- Energy Efficiency in Existing Buildings (ANSI Approved/IES Co-sponsored)
Free Download
ASHRAE 100-2015 Addenda c
Published Date: 2017
Addenda c to Standard 100-2015 -- Energy Efficiency in Existing Buildings (ANSI Approved/IES Co-sponsored)
Free Download