ASTM F2129-08 PDF

ASTM F2129-08 PDF

Name:
ASTM F2129-08 PDF

Published Date:
10/01/2008

Status:
Active

Description:

Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$17.4
Need Help?

1.1 This test method assesses the corrosion susceptibility of small, metallic, implant medical devices, or components thereof, using cyclic (forward and reverse) potentiodynamic polarization. Examples of device types that may be evaluated by this test method include, but are not limited to, vascular stents, ureteral stents (Specification F 1828), filters, support segments of endovascular grafts, cardiac occluders, aneurysm or ligation clips, staples, and so forth.

1.2 This test method is used to assess a device in its final form and finish, as it would be implanted. These small devices should be tested in their entirety. The upper limit on device size is dictated by the electrical current delivery capability of the test apparatus (see Section 6). It is assumed that test methods, such as Reference Test Method G 5 and Test Method G 61 have been used for material screening.

1.3 Because of the variety of configurations and sizes of implants, this test method provides a variety of specimen holder configurations.

1.4 This test method is intended for use on implantable devices made from metals with a relatively high resistance to corrosion.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.REFERENCE:

ASTM Standards:

D1193 Specification for Reagent Water

E177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods

E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method

F1828 Specification for Ureteral Stents

G3 Practice for Conventions Applicable to Electrochemical Measurements in Corrosion Testing

G5 Reference Test Method for Making Potentiostatic and Potentiodynamic Anodic Polarization Measurements

G15 Terminology Relating to Corrosion and Corrosion Testing

G61 Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements for Localized Corrosion Susceptibility of Iron-, Nickel-, or Cobalt-Based Alloys


File Size : 1 file , 140 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 9
Published : 10/01/2008
Redline File Size : 2 files , 250 KB

History

ASTM F2129-24
Published Date: 09/01/2024
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
$18.9
ASTM F2129-19a
Published Date: 01/15/2019
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
$22.5
ASTM F2129-19
Published Date: 01/01/2019
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
$17.4
ASTM F2129-17b
Published Date: 12/01/2017
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
$17.4
ASTM F2129-17a
Published Date: 11/15/2017
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
$17.4
ASTM F2129-08
Published Date: 10/01/2008
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
$17.4
ASTM F2129-06
Published Date: 05/15/2006
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
$17.4
ASTM F2129-04
Published Date: 05/01/2004
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
$17.4
ASTM F2129-03
Published Date: 11/01/2003
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
$17.4
ASTM F2129-01
Published Date: 07/10/2001
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
$17.4

Related products

ASTM E825-98(2023)
Published Date: 02/01/2023
Standard Specification for Phase Change-Type Disposable Fever Thermometer for Intermittent Determination of Human Temperature
$15
ASTM F2102-17
Published Date: 09/01/2017
Standard Guide for Evaluating the Extent of Oxidation in Polyethylene Fabricated Forms Intended for Surgical Implants
$14.4
ASTM F2103-18
Published Date: 06/01/2018
Standard Guide for Characterization and Testing of Chitosan Salts as Starting Materials Intended for Use in Biomedical and Tissue-Engineered Medical Product Applications
$14.4
ASTM F961-20
Published Date: 02/01/2020
Standard Specification for 35Cobalt-35Nickel-20Chromium-10Molybdenum Alloy Forgings for Surgical Implants (UNS R30035)
$13.2

Best-Selling Products

CAN/CSA 2/1/9075
Published Date: 03/01/2002
Information Technology - Database Languages - SQL - Part 2: Foundation (SQL/Foundation) (Adopted ISO/IEC 9075-2:1999, first edition, 1999-12-01)
$88.5
CAN/CSA 50001:11 (R2016)
Published Date: 06/01/2011
Energy management systems - Requirements with guidance for use (Adopted ISO 50001:2011, first edition, 2011-06-15)
$33
CAN/CSA 6.19-01 (R2016)
Published Date: 10/03/2001
Residential Carbon Monoxide Alarming Devices
$101.7
CAN/CSA 601.2.1-92
Published Date:
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Medical Electron Accelerators in the Range 1 MeV to 50 MeV (Adopted IEC 601-2-1:1981)
$14.1
CAN/CSA 601.2.11-92
Published Date:
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Gamma Beam Therapy Equipment (Adopted IEC 601- 2-11:1987)
$14.1
CAN/CSA 601.2.14-92
Published Date:
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Electroconvulsive Therapy Equipment (Adopted IEC 601-2-14:1989)
$11.1