1.1 The purpose of this specification is to provide a test procedure and performance requirement for the puncture resistance of materials used in the construction of containers for discarded medical needles and other sharps. This test specification will establish (1) the average puncture force and (2) a minimum value of puncture force that container material(s) must withstand when following the test procedure described in Section 6. This specification shall be applicable to regions of uniform material and thickness, and needle contact areas as defined in 3.1.7 and 3.1.9. Materials meeting the performance requirements of Section 4 will be considered "puncture resistant." This specification will not evaluate the construction of, or provide pass/fail criteria for, a sharps container.

1.2 This specification provides a test procedure to determine if all regions of one container meet the material puncture resistance requirements. It does not define the number of additional test containers required to achieve a statistically valid sample of a manufacturing lot or process. An appropriate sampling plan shall be determined by the test requester, as this depends upon the manufacturing process variability, manufacturing lot size, and other factors, such as end-user requirements.

1.3 This specification is intended to evaluate the performance of materials used in the construction or manufacture of sharps containers under controlled laboratory conditions, and at normal room temperature (see 6.1). (Warning-This specification only characterizes material puncture resistance at normal room temperatures. Applications of sharps containers outside the range of 23 ± 2°C (beyond the clinical environment, such as usage in emergency vehicles), require further material characterization by the product specifier to determine suitable use.)

1.4 The values stated in inch/pound are to be regarded as the standard. The SI values given in parentheses are for information only.

1.5 The following hazard caveat pertains only to the test procedure portion, Section 6, of this specification.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 90 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 5
Published : 02/01/2008

History

ASTM F2132-01(2008)e1
Published Date: 02/01/2008
Standard Specification for Puncture Resistance of Materials Used in Containers for Discarded Medical Needles and Other Sharps (Withdrawn 2017)
$17.4
ASTM F2132-01(2008)
Published Date: 02/01/2008
Standard Specification for Puncture Resistance of Materials Used in Containers for Discarded Medical Needles and Other Sharps
$17.4
ASTM F2132-01
Published Date: 08/10/2001
Standard Specification for Puncture Resistance of Materials Used in Containers for Discarded Medical Needles and Other Sharps
$17.4

Related products

ASTM F1906-98(2003)
Published Date: 11/01/2003
Standard Practice for Evaluation of Immune Responses In Biocompatibility Testing Using ELISA Tests, Lymphocyte, Proliferation, and Cell Migration (Withdrawn 2011)
$17.4
ASTM F2528-06(2023)
Published Date: 07/01/2023
Standard Test Methods for Enteral Feeding Devices with a Retention Balloon
$17.1
ASTM F2381-19
Published Date: 10/01/2019
Standard Test Method for Evaluating Trans-Vinylene Yield in Irradiated Ultra-High Molecular Weight Polyethylene Fabricated Forms Intended for Surgical Implants by Infrared Spectroscopy
$15
ASTM F749-20
Published Date: 02/01/2020
Standard Practice for Evaluating Material Extracts by Intracutaneous Injection in the Rabbit
$13.2

Best-Selling Products

VDI/DGQ 3441
Published Date: 03/01/1977
Statistical Testing of the Operational and Positional Accuracy of Machine Tools; Basis
VDI/DGQ 3442
Published Date: 03/01/1977
Statical examination of exactly working of turing machines
VDI/DGQ 3443
Published Date: 03/01/1977
Statistical examination of exactly working of milling machines
VDI/DGQ 3444
Published Date: 09/01/1978
Statistical control of exactly working and positioning of coordinate drilling machines and machining centers
VDI/DGQ 3445 Sheet 1
Published Date: 03/01/1977
Statistical examination of exactly working of grinding machines; fundamentels
VDI/DGQ 3445 Sheet 2
Published Date: 03/01/1977
Statistical examination of exactly working of grinding machines; external cylindrical grinding machines with center points; plunge-cut grinding operation