1.1 This practice is intended to establish the procedures for validation, calibration, and certification of walkway tribometers.

1.2 This practice provides a walkway tribometer supplier with a procedure and suite of reference surfaces to validate his walkway tribometer by properly ranking and differentiating the surfaces.

1.3 This practice provides the user of a walkway tribometer with a procedure and suite of reference surfaces to test calibration of his instrument.

1.4 This practice provides a procedure through which an entity may certify a walkway tribometer model, signifying that the walkway tribometer model has a completed and documented validation and interlaboratory study.

1.5 This practice describes the necessary materials, specifications, and the cleaning process for reference materials, as well as the requirements for the validation of a supplier???s walkway tribometer and calibration of a user???s walkway tribometer.

1.6 This practice applies to walkway tribometers without reference to the nature of the scale of the readings produced by them. The scale used in the reports of validation and calibration must be the same, and are to be those of the instrument or defined for the instrument.

1.7 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only and are not considered standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 89 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 5
Published : 10/15/2012

History

ASTM F2508-23
Published Date: 08/15/2023
Standard Practice for Validation of Walkway Tribometry Using Research-based Reference Materials
$18.9
ASTM F2508-16e1
Published Date: 07/01/2016
Standard Practice for Validation, Calibration, and Certification of Walkway Tribometers Using Reference Surfaces
$22.5
ASTM F2508-13
Published Date: 04/01/2013
Standard Practice for Validation, Calibration, and Certification of Walkway Tribometers Using Reference Surfaces
$17.4
ASTM F2508-12a
Published Date: 11/01/2012
Standard Practice for Validation, Calibration, and Certification of Walkway Tribometers Using Reference Surfaces
$17.4
ASTM F2508-12
Published Date: 10/15/2012
Standard Practice for Validation, Calibration, and Certification of Walkway Tribometers Using Reference Surfaces
$17.4
ASTM F2508-11
Published Date: 03/15/2011
Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces
$17.4

Related products

ASTM F2032-22
Published Date: 06/15/2022
Standard Specification for Helmets Used for BMX Cycling
$14.4
ASTM F2124-13
Published Date: 05/01/2013
Standard Practice for Testing Treestand Ladder, Tripod Stand and Climbing Stick Load Capacity (Withdrawn 2017)
$15
ASTM F2397-18
Published Date: 10/01/2018
Standard Specification for Protective Headgear Used in Combative Sports
$14.4

Best-Selling Products

281491 37798
Published Date:
Chemical Resistance Guide for Elastomers IV