1.1 This test method covers a procedure for establishing Pressure Rating for PVC schedule 40 and 80 socket-type fittings by evaluating fitting failure test data derived by testing water-filled assemblies of pipe and fittings.

1.2 Unless the data approximates a straight line, when calculated using log-log coordinates, it is not possible to assign a pressure rating to that product or sample of product. Data that exhibit high scatter, or a downward curve, due to low long term data, will give low extrapolated values that are more conservative when calculated using log-log co-ordinates. In addition, this downward curve will show as higher scatter, and where the lower confidence level limits are not met the data shall be classified as unsuitable. (See Note 1)

Note 1

This test method is similar to that used in Test Method D 2837, which has been used for about 30 years to establish the HDS of plastic pipe materials and is the basis for all pressure ratings assigned to plastic pipes.

1.3 The products covered by this test method are schedule 40 or 80 molded PVC fittings that conform to Specifications D 2466 or D 2467.

1.4 The pressure ratings developed using this test method applies only to fittings identical to the ones that were tested. Some variables that will affect the pressure rating are - pipe size, pattern, mold design, material, and molding conditions.

1.5 The values in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.6 The testing procedure used to obtain the fitting failure data shall be as described in those sections of Test Method D 1598, that are referenced in Section of this test method.

1.7 The products covered by this test method are intended for use in the distribution of pressurized liquids at 73°F. When appropriate, the design engineer must consider the effects of elevated temperature and chemical compatibility of the liquid with the fitting material and apply necessary design factors.

This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the application of regulatory limitations prior to use.

Note 2

Pressurized (compressed) air or other compressed gases contain large amounts of stored energy which present serious safety hazards should a system fail for any reason.


File Size : 1 file , 66 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 3
Published : 08/01/2006

History

ASTM F2536-17(2022)
Published Date: 02/01/2022
Standard Guide for Installing Plastic DWV Piping Suspended from On-Grade Slabs
$14.4
ASTM F2536-17
Published Date: 11/01/2017
Standard Guide for Installing Plastic DWV Piping Suspended from On-Grade Slabs
$16.8
ASTM F2536-06b(2011)
Published Date: 02/01/2011
Standard Guide for Installing Plastic DWV Piping Suspended from On-Grade Slabs
$15
ASTM F2536-06a
Published Date: 08/01/2006
Standard Guide for Installing Plastic DWV Piping Suspended from On-Grade Slabs
$8.7
ASTM F2536-06b
Published Date: 05/01/2006
Standard Guide for Installing Plastic DWV Piping Suspended from On-Grade Slabs
$15
ASTM F2536-06
Published Date: 05/01/2006
Standard Guide for Installing Plastic DWV Piping Suspended from On-Grade Slabs
$15

Related products

ASTM D2122-22
Published Date: 07/01/2022
Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
$16.2
ASTM F1504-21e1
Published Date: 07/31/2021
Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation
$16.2
ASTM D2241-24
Published Date: 04/01/2024
Standard Specification for Poly(Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series)
$18.9
ASTM D2996-23
Published Date: 10/01/2023
Standard Specification for Filament-Wound “Fiberglass” (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe
$18.9

Best-Selling Products

AENOR EA 0007
Published Date: 09/07/2016
Requisitos del sistema de seguimiento y agregación de los precios del papel para reciclar.
$12.9
AENOR EA 0014
Published Date: 02/14/2003
Marcado por impresión de los elementos calefactores que utilizan cable calefactor según la Norma UNE 21155-1.
$5.4
AENOR EA 0032
Published Date: 07/11/2007
Equipos estabilizadores de tensión y reductores de flujo luminoso en cabecera de línea. Requisitos generales y de seguridad
$23.7
AENOR EA 0039
Published Date: 02/04/2009
Cables multiconductores de tensión asignada 0,6/1 kV no propagadores del incendio, aislados con polietileno reticulado y con cubierta de poliolefina, para utilizar como instalación fija en circuitos de control.
$18.9
AENOR EA 0042
Published Date: 12/23/2014
Aparamenta de baja tensión. Equipos auxiliares. Conjuntos de bloques de conexión para la verificación de contadores de energía.
$22.2
AENOR EA 0051
Published Date: 12/23/2014
Cables eléctricos de distribución con aislamiento extruido, de tensión asignada desde 3,6/6 (7,2) kV hasta 20,8/36 (42) kV inclusive. Cables unipolares y unipolares reunidos con aislamiento de HPTE. Cables con cubierta de compuesto de poliolefina (tipo 1, tipo 2 y tipo 3)
$22.2