ASTM F2873-20 PDF

ASTM F2873-20 PDF

Name:
ASTM F2873-20 PDF

Published Date:
05/01/2020

Status:
Active

Description:

Standard Practice for the Installation of Self-Leveling Underlayment and the Preparation of Surface to Receive Resilient Flooring

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
astm-f2873-20_2122658

Choose Document Language:
15.00 €
Need Help?

1.1 This practice covers the installation of self-leveling underlayments, which may include a priming system, over solid wood, wood structural panel subfloors, over concrete, and over certain solidly bonded existing flooring systems such as epoxy floors, ceramic and natural stone tiles, terrazzo, metal subfloors and foils such as steel, copper and lead, solidly bonded patching and other leveling materials as well as properly prepared non water-soluble adhesive residues as recommended by the underlayment manufacturer. This practice also covers the preparation of the self-leveling underlayment's surface prior to the installation of resilient flooring.

1.2 This practice points out the factors that are required to be controlled while installing a self-leveling underlayment to be used as a substrate for resilient flooring.

1.3 This practice does not cover the structural adequacy of the subfloor. The structural integrity of assemblies is governed by local building codes and may be superseded by the resilient flooring manufacturer's and the self-leveling underlayment manufacturer's requirements.

1.4 This practice does not supersede the self-leveling underlayment manufacturer's, adhesive manufacturer's or resilient flooring manufacturer's written instructions. Consult the individual manufacturer for specific recommendations.

1.5 Some self-leveling underlayments are not suitable for use on concrete slabs on or below grade due to potential moisture problems arising from moisture intrusion. However, most of the self-leveling underlayments may be suitable for use on and below grade if an adequate and effective vapor retarder or vapor barrier is present directly beneath the concrete slab or an effective moisture remediation system has been installed beneath the surface of the self-leveling underlayment. Consult the manufacturer of the self-leveling underlayment and flooring system for specific recommendations.

1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.7 This practice does purport to address the necessity for or the safe or correct removal of asbestos containing materials. Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysoltile asbestos, refer to “Safe Use of Chrysotile Asbestos: A Manual on Preventive and Control Measures.”2

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 83 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 5
Published : 05/01/2020
Redline File Size : 2 files , 160 KB

History

ASTM F2873-20
Published Date: 05/01/2020
Standard Practice for the Installation of Self-Leveling Underlayment and the Preparation of Surface to Receive Resilient Flooring
15.00 €
ASTM F2873-19
Published Date: 12/01/2019
Standard Practice for the Installation of Self-Leveling Underlayment and the Preparation of Surface to Receive Resilient Flooring
18.00 €
ASTM F2873-18
Published Date: 07/15/2018
Standard Practice for the Installation of Self-Leveling Underlayment and the Preparation of Surface to Receive Resilient Flooring
18.00 €
ASTM F2873-13
Published Date: 06/01/2013
Standard Practice for the Installation of Self-Leveling Underlayment and the Preparation of Surface to Receive Resilient Flooring
17.40 €

Related products

ASTM D3897-18
Published Date: 09/01/2018
Standard Test Method for Calculation of Basicity of Chrome Tanning Liquors
12.60 €
ASTM D1610-18(2023)
Published Date: 01/01/2023
Standard Practice for Conditioning Leather and Leather Products for Testing
15.00 €
ASTM F373-13(2022)
Published Date: 06/01/2022
Standard Test Method for Embossed Depth of Resilient Floor Coverings
14.40 €

Best-Selling Products

INCITS/ISO/IEC 10641
Published Date: 01/01/1993
Information technology - Computer graphics and image processing - Conformance testing of implementations of graphics standards
INCITS/ISO/IEC 10967-1
Published Date: 01/01/1994
Information technology - Language independent arithmetic - Part 1: Integer and floating point arithmetic
INCITS/ISO/IEC 10994
Published Date: 01/01/1992
Information technology - Data interchange on 90 mm flexible disk cartridges using modified frequency modulation recording at 31 831 ftprad on 80 tracks on each side - ISO Type 303
25.50 €
INCITS/ISO/IEC 11072
Published Date: 01/01/1992
Information technology - Computer graphics - Computer Graphics Reference Model
INCITS/ISO/IEC 11319
Published Date: 01/01/1993
Information technology - 8 mm wide magnetic tape cartridge for information interchange - Helical scan recording
INCITS/ISO/IEC 11557
Published Date: 01/01/1992
Information technology - 3,81 mm wide magnetic tape cartridge for information interchange - Helical scan recording - DDS-DC format using 60 m and 90 m length tapes