ASTM F855-09 PDF

ASTM F855-09 PDF

Name:
ASTM F855-09 PDF

Published Date:
05/01/2009

Status:
Active

Description:

Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$19.5
Need Help?

1.1 These specifications cover the equipment making up the temporary grounding system used on de-energized electric power lines, electric supply stations, and equipment.

1.2 It is common practice for the users of protective grounding equipment to prepare complete instructions and regulations to govern in detail the correct use and maintenance of such equipment.

1.3 The uses and maintenance of this equipment are beyond the scope of these specifications.

1.4 These specifications for a system of protective grounding utilizing copper cables are covered in four parts, as follows:

Sections
Clamps for Temporary Protective Grounds4-16
Ferrules for Temporary Protective Grounds17-30
Cables for Temporary Protective Grounds31-39
Protective Grounds (Complete Assembly With Clamps, Ferrules, and Cable)40-52

1.5 Each of the four parts is an entity of itself, but is listed as a part of the system for completeness and clarification.

1.6 Currents presented in Table 1 are based upon cable melting times, as determined from equations by I. M. Onderdonk and are to used in situations involving an asymmetry value less than 20 % (X/R 1.8). See Appendix X3.

1.6.1 Currents presented in Table 2 are based upon the values from EPRI Project RP2446 Computer Program RTGC "A Desktop Computer Program for Calculating Rating of Temporary Grounding Cables" and are to be used in situations involving an asymmetry value greater then 20 % (X/R 1.8), see Appendix X4.

Note 1 - Table 1 represents the clamp and assembly ratings that existed prior to this revision. Table 2 represents new ratings now required for high X/R situations.

1.6.2 See Appendix X3 and Appendix X4 for a discussion of these topics.

1.7 The values stated in Newton-Meter units are to be regarded as the standard. The values in parentheses are the inch-pound units.

1.8 The following precautionary caveat pertains to the test method portions, Sections 12 and 25 of these specifications: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 800 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 19
Published : 05/01/2009
Redline File Size : 2 files , 1.5 MB

History

ASTM F855-23
Published Date: 02/01/2023
Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment
$20.7
ASTM F855-20
Published Date: 09/15/2020
Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment
$22.8
ASTM F855-19a
Published Date: 11/01/2019
Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment
$20.7
ASTM F855-19
Published Date: 08/01/2019
Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment
$20.1
ASTM F855-17
Published Date: 12/15/2017
Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment
$19.5
ASTM F855-14
Published Date: 10/01/2014
Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment
$19.5
ASTM F855-09
Published Date: 05/01/2009
Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment
$19.5
ASTM F855-04
Published Date: 09/01/2004
Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment
$19.5
ASTM F855-03
Published Date: 11/01/2003
Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment
$19.5
ASTM F855-97e1
Published Date: 01/01/1997
Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment
$19.5

Related products

ASTM D1169-19a
Published Date: 10/01/2019
Standard Test Method for Specific Resistance (Resistivity) of Electrical Insulating Liquids
$15
ASTM F1959/F1959M-24b
Published Date: 07/01/2024
Standard Test Method for Determining the Arc Rating of Materials for Clothing
$20.7
ASTM D1534-95(2017)
Published Date: 06/01/2017
Standard Test Method for Approximate Acidity in Electrical Insulating Liquids by Color-Indicator Titration
$12.6
ASTM F479-06(2022)
Published Date: 02/01/2022
Standard Specification for In-Service Care of Insulating Blankets