Description:

Standard Practice for Assessment of Compatibility of Biomaterials for Surgical Implants with Respect to Effect of Materials on Muscle and Bone

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$17.4
Need Help?

1.1 This practice provides a series of experimental protocols for biological assays of tissue reaction to nonabsorbable biomaterials for surgical implants. It assesses the effects of the material on animal tissue in which it is implanted. The experimental protocol is not designed to provide a comprehensive assessment of the systemic toxicity, immune response, carcinogenicity, teratogenicity, or mutagenicity of the material since other standards deal with these issues. It applies only to materials with projected applications in humans where the materials will reside in bone or soft tissue in excess of 30 days and will remain unabsorbed. It is recommended that short-term assays, according to Practice F 763, first be performed. Applications in other organ systems or tissues may be inappropriate and are therefore excluded. Control materials will consist of any one of the metal alloys in Specifications F 67, F 75, F 90, F 136, F 138, or F 562, high purity dense aluminum oxide as described in Specification F 603, ultra high molecular weight polyethylene as stated in Specification F 648 or USP polyethylene negative control.

1.2 This practice is a combination of Practice F 361 - 80 and Practice F 469 - 78. The purpose, basic procedure, and method of evaluation of each type of material are similar; therefore, they have been combined.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 41 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 5
Published : 11/01/2003

History

ASTM F981-23
Published Date: 09/01/2023
Standard Practice for Assessment of Muscle and Bone Tissue Responses to Long-Term Implantable Materials Used in Medical Devices
$17.1
ASTM F981-04(2010)
Published Date: 06/01/2010
Standard Practice for Assessment of Compatibility of Biomaterials for Surgical Implants with Respect to Effect of Materials on Muscle and Bone
$17.4
ASTM F981-04
Published Date: 05/01/2004
Standard Practice for Assessment of Compatibility of Biomaterials for Surgical Implants with Respect to Effect of Materials on Muscle and Bone
$17.4
ASTM F981-99(2003)
Published Date: 11/01/2003
Standard Practice for Assessment of Compatibility of Biomaterials for Surgical Implants with Respect to Effect of Materials on Muscle and Bone
$17.4
ASTM F981-99
Published Date: 05/10/1999
Standard Practice for Assessment of Compatibility of Biomaterials for Surgical Implants with Respect to Effect of Materials on Muscle and Bone
$17.4

Related products

ASTM F623-19
Published Date: 03/01/2019
Standard Performance Specification for Foley Catheter
$15.6
ASTM F1717-21
Published Date: 05/01/2021
Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model
$20.7
ASTM F1266-89(2008)
Published Date: 02/01/2008
Standard Performance Specification for Cerebral Stereotactic Instruments (Withdrawn 2017)
$17.4
ASTM F1672-14(2019)
Published Date: 08/15/2019
Standard Specification for Resurfacing Patellar Prosthesis (Withdrawn 2023)
$22.5

Best-Selling Products

CAN/CSA-IEC 31010:20
Published Date: 04/01/2020
Risk management - Risk assessment techniques (Adopted IEC 31010:2019, second edition, 2019-06)
$70.5
CAN/CSA-IEC 61000-4-15:12 (R2021)
Published Date: 06/01/2012
CAN/CSA-IEC 61000-4-15:12 - Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications (Adopted IEC 61000-4-15:2010, edition 2.0, 2010-08)
$69.3
CAN/CSA-IEC 61000-4-18:14 (R2023)
Published Date: 10/01/2014
Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test (Adopted IEC 61000-4-18:2011, edition 1:2006 consolidated with amendment 1:2010)
$78
CAN/CSA-IEC 61000-4-2:12 (R2022)
Published Date: 06/30/2012
Electromagnetic Compatibility (EMC) - Part 4-2: Testing and Measurement Techniques - Electrostatic Discharge Immunity Test (Adopted CEI/IEC 61000-4-2:1995 + A1:1998, edition 1.1, 1999-05)
$84.9
CAN/CSA-IEC 61000-4-3:21
Published Date: 05/01/2021
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test (IEC 61000-4-3:2006+A1:2007+A2:2010, IDT)
$184.8
CAN/CSA-IEC 61000-4-30:16
Published Date: 08/05/2022
Amendment 1 to Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods (Adopted IEC 61000-4-30:2015, third edition, 2015-02)
$3.3