AWS C3.3 PDF

AWS C3.3 PDF

Name:
AWS C3.3 PDF

Published Date:
01/01/2008

Status:
[ Revised ]

Description:

Recommended Practices for Design, Manufacture, and Examination of Critical Brazed Components

Publisher:
American Welding Society

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$22.5
Need Help?

These recommended practices encompass those procedures that should be followed in the design, manufacture, and inspection of brazed joints for critical components in order to assure their reliability in service.

The procedures recommended represent the best current practice and are necessary to the control of brazed joint quality. These practices are applicable to all products and brazing processes. Whenever any or some of these practices are omitted when producing critical components, the omission should be the result of a rational decision, not the result of a lack of knowledge of the best practice.

This document is divided into sections addressing materials, design, manufacturing, and inspection. These sections are followed by Annex A, which presents sample specifications that are intended as guides for the preparation of the user’s documents; Annex B, which presents a discussion of brazing risk management; Annex C, which presents a table relating to the quantification of the scope and magnitude of braze-induced discontinuities; and Annex D, which presents guidelines for the preparation in inquiries for AWS technical committees.

Procedures for the protection of the safety and health of those performing brazing and related operations are of great importance. Among the potential hazards to be considered are exposure to fumes and gases, radiation, and toxic materials. However, safety and health considerations are not addressed in this standard. The user is advised to consult (1) the manufacturer’s instructions and Material Safety Data Sheets (MSDSs) for the material and equipment used and (2) federal, state, and local regulations. Additional information on safety and health is included in ANSI Z49.1, Safety in Welding, Cutting, and Allied Processes, and Chapter 10, “Safety and Health,” of the American Welding Society’s (AWS) Brazing Handbook.


ANSI : ANSI Approved
Edition : 3
File Size : 1 file , 270 KB
Number of Pages : 44
Published : 01/01/2008

History

AWS C3.3
Published Date: 01/01/2008
Recommended Practices for the Design, Manufacture, and Examination of Critical Brazed Components
$24
AWS C3.3
Published Date: 01/01/2008
Recommended Practices for Design, Manufacture, and Examination of Critical Brazed Components
$22.5
AWS C3.3
Published Date: 01/01/2002
Recommended Practices for Design, Manufacture, and Examination of Critical Brazed Components
$19.2
AWS C3.3
Published Date: 01/01/1980
Recommended Practices for Design, Manufacture, and Inspection of Critical Brazed Components
$18

Related products

AWS A4.4M
Published Date: 01/01/2001
Standard Procedures for Determination of Moisture Content of Welding Fluxes and Welding Electrode Flux Coverings
$24
AWS C4.5M
Published Date: 01/01/2000
Uniform Designation System for Oxyfuel Nozzles
$33
AWS A5.22/A5.22M
Published Date: 01/01/2024
Specification for Stainless Steel Flux Cored and Metal Cored Welding Electrodes and Rods
$25.2
AWS B2.1-8-213
Published Date: 01/01/2023
Standard Welding Procedure Specification (SWPS) for Shielded Metal Arc Welding of Austenitic Stainless Steel (M-8/P-8, Group 1), 1/8 in [ 3 mm] through 1-1/2 in [38 mm] Thick, E3XX-XX, As-Welded Condition, Primarily Pipe Applications
$98.4

Best-Selling Products

AAMI/ISO 10993-1:2003
Published Date: 12/01/2003
Biological Evaluation of Medical Devices Part 1: Evaluation and Testing
$26.4
AAMI/ISO 10993-1:2009 Erratum
Published Date: 06/10/2013
Erratum for Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
Free Download
AAMI/ISO 10993-1:2009/(R)2013
Published Date: 09/03/2009
Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process; Includes Erratum (2013)
AAMI/ISO 10993-1:2018
Published Date: 04/27/2020
Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
$82.5
AAMI/ISO 10993-10:2010/(R)2014
Published Date: 09/04/2010
Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization
$82.5
AAMI/ISO 10993-11:2006/(R)2014
Published Date: 10/19/2006
Biological evaluation of medical devices - Part 11: Tests for systemic toxicity