Description:

Transient Cross-Connections: A Source of Microbial Risk in Pressurized Systems

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The objective of this study was to determine routes and severity of pathogen entry into the distribution system and to recommend monitoring and control strategies. This report focuses on the measurement of pathogens external to drinking water pipelines and pressure fluctuations within the distribution system. To determine the opportunity of pathogens to enter thedistribution system, water and soil samples external to the pipe system were analyzed for total coliform, fecal coliform, Bacillus subtilis, Clostridium perfringens, bacteriophage, and enteric viruses. Water utilities were instructed to collect soil and water samples whenever distribution system pipelines were exposed for repairs or construction. Sterile trowels and containers were provided to collect soil samples immediately adjacent to the pipeline from an undisturbed portion of the pit. Water samples (if available) were collected from water within the excavation pit. Both samples were shipped on ice via overnightcarrier to the laboratory for analysis. Both water and soil samples were analyzed for indicator organisms and enteric viruses. Soil samples (10 gm) were mixed with 90 ml of sterile reagent-grade water in a sterile container and mixed for 10 min using a magnetic stirrer. Typically 0.1 to 10 mL of this solution was quickly transferred (to avoid settling) to microbiological media for analysis. Includes 5 references, tables, figures.
Edition : Vol. - No.
File Size : 1 file , 300 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 9
Published : 06/01/2001

History


Related products

AWWA ACE54412
Published Date: 06/01/2001
Studies on the Formation of N-Nitrosodimethylamine (NDMA) in Drinking Water: A New Chloramination Disinfection By-Product
$7.2
AWWA ACE54440
Published Date: 06/01/2001
The Process of Establishing an Early Warning Monitoring Network on the Upper Mississippi River
$7.2
AWWA ACE54257
Published Date: 06/01/2001
Influence of Gas-Water Interfaces on the Transport and Spatial Distribution of Cryptosporidium Parvum Oocysts in Model Porous Media
$7.2
AWWA ACE54393
Published Date: 06/01/2001
If the Regulation Fits, Wear It -- If Not, Stretch It: A Case Study of Compliance With the Lead and Copper Rule
$7.2

Best-Selling Products

VDI/VDE/DGQ/DKD 2622 Sheet 10
Published Date: 06/01/2004
Calibration of measurement equipments for electrical quantities - High-frequency fieldstring meters
VDI/VDE/DGQ/DKD 2622 Sheet 11
Published Date: 09/01/2003
Calibration of measurement equipments for electrical quantities - Spectrum analyzers
VDI/VDE/DGQ/DKD 2622 Sheet 12
Published Date: 06/01/2004
Calibration of measurement equipment for electrical quantities - Test receiver
VDI/VDE/DGQ/DKD 2622 Sheet 15.4 - DRAFT
Published Date: 06/01/2007
Draft Document - Calibration of measuring equipment for electrical quantities - Passive measuring equipment for use in EMC-applications - Current clamps
VDI/VDE/DGQ/DKD 2622 Sheet 15.4
Published Date: 05/01/2010
Calibration of measuring equipment for electrical quantities - Passive measuring equipment for use in EMC-applications - Current clamps
VDI/VDE/DGQ/DKD 2622 Sheet 1
Published Date: 01/01/2001
Calibration of measuring equipment for electrical quantities - Fundamentals