AWWA ACE54430 PDF

AWWA ACE54430 PDF

Name:
AWWA ACE54430 PDF

Published Date:
06/01/2001

Status:
Active

Description:

Solving Copper Corrosion Problems While Maintaining Lead Control in a High Alkalinity Water Using Orthophosphate

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
Lead and Copper Rule sampling in 1992 uncovered high copper levels in many homes in the Indian Hill Water Works water system. The 90th percentile copper and lead levels were 1.63 mg/L and 0.012 mg/L, respectively. Indian Hill Water Works (IHWW) supplies water to several suburban communities to the east of Cincinnati, Ohio. Finished water hardness is approximately 150 mg/L as CaCO3, total alkalinity approximately 250 mg/L as CaCO3, dissolved inorganic carbon (DIC) approximately 60-65 mg C/L, and pH ranges from about 7.1 to 7.5, mostly near 7.3. Final treatment consists of chlorination, fluoridation, and at different times, addition of caustic and/or corrosion inhibitor. Historically, water heater failures and high copper levels resulting in blue water were reported in the 1950s, and caustic addition was used to elevate the pH to as high as 8 at different times throughout the next 3 decades. In the late 1980s and early 1990s, zinc orthophosphate treatment was employed, which was mostly successful for lead and inconsistently successful for copper. In 1997 with the 90th percentile still at 1.54 mg/L for copper, the zinc orthophosphate treatment was withdrawn. In 1998, new pilot tests were carried out in collaboration with the Water Supply and Water Resources Division of the US Environmental Protection Agency in Cincinnati to do some new pilot testing and a more systematic analysis of copper corrosion control chemistry. Tests compared pH adjustment, partial DIC removal through anion-exchange and increasing orthophosphate dosing. The most economical alternative identified was an increased orthophosphate residual of 3 mg/L as PO4. The recommended treatment wasimplemented beginning in 1999. Lead levels were below 0.005 mg/l for the 90th percentile, and the 90th percentile copper levels were reduced to 1.04 mg/L, for the fall 1999 and Spring 2000 sampling rounds. Copper levels remain consistently below the Action Level, and IHWW has now successfully met simultaneous lead and copper control requirements of the regulations and is now in "reduced monitoring" status. Includes 21 references, table, figures.
Edition : Vol. - No.
File Size : 1 file , 7.7 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 22
Published : 06/01/2001

History


Related products

AWWA ACE54421
Published Date: 06/01/2001
Self Evaluation and Capacity Development in Small Systems
$7.2
AWWA ACE54289
Published Date: 06/01/2001
Energy Conservation Measures for a Large Metropolitan Groundwater Utility
$7.2
AWWA ACE54297
Published Date: 06/01/2001
San Diego Water Department's Proactive Approach to Public Information/Outreach for the Miramar Water Treatment Plant Upgrade/Extension Project
$7.2
AWWA ACE54395
Published Date: 06/01/2001
Simulation Exercise Prepares Utility for Public Notification
$7.2

Best-Selling Products

SN-ISO/TS 10993-19:2006
Published Date: 07/01/2014
Biological evaluation of medical devices — Part 19: Physico-chemical, morphological and topographical characterization of materials
SN-ISO/TS 10993-19:2020
Published Date: 12/14/2020
Biological evaluation of medical devices — Part 19: Physico-chemical, morphological and topographical characterization of materials
SN-ISO/TS 10993-20:2006
Published Date: 07/01/2014
Biological evaluation of medical devices — Part 20: Principles and methods for immunotoxicology testing of medical devices
SN-ISO/TS 14067:2013
Published Date: 07/01/2013
Greenhouse gases — Carbon footprint of products — Requirements and guidelines for quantification and communication
SN-ISO/TS 14092:2020
Published Date: 09/02/2021
Adaptation to climate change - Requirements and guidance on adaptation planning for local governments and communities
SN-ISO/TS 14812:2022
Published Date: 09/20/2023
Intelligent transport systems - Vocabulary