Description:

UV Reactor Analysis Using CFD and UV Intensity Models

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The ultraviolet (UV) dose delivered by a UV disinfection system can be predicted by computational fluid dynamics (CFD) and UV intensity models for varying UV transmittance (UVT), inactivation kinetics and system operating conditions. This study involved CFD modeling to evaluate the effect of these factors on the reduction equivalent dose (RED) and RED bias of two UV system designs. The RED bias is a correction factor that accounts for differences in the RED for the challenge microbe used during reactor validation and the target pathogen RED. Results indicate that RED bias significantly decreases as the UVT increases and as the UV sensitivity of the challenge microbe approaches that of the target microbe. Results also demonstrate that RED bias varies from reactor to reactor. Includes 10 references, table, figures.
Edition : Vol. - No.
File Size : 1 file , 500 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 10
Published : 06/17/2004

History


Related products

AWWA ACE59825
Published Date: 06/17/2004
Getting into the Thick of Actiflo Residuals Handling
$7.2
AWWA ACE59858
Published Date: 06/17/2004
Identifying Particulate Matter in Distribution Water and at the Customer's Tap
$7.2
AWWA ACE59911
Published Date: 06/17/2004
Membrane Process Integrity Testing
$7.2
AWWA ACE59930
Published Date: 06/17/2004
Comparison of Three Methodologies for the Detection of Cryptosporidium in Water
$7.2

Best-Selling Products

ATIS 0100001.2004(S2018)
Published Date: 10/01/2004
User Plane Security Guidelines and Requirements for ETS
$18
ATIS 0100002
Published Date: 07/01/2004
Reliability Aspects of Next Generation Networks
$43.5
ATIS 0100003
Published Date: 11/01/2004
User Plane Priority Levels for IP Networks and Services
$18
ATIS 0100004
Published Date: 01/01/2006
Availability & Restorability Aspects of Emergency Telecommunications Service (ETS)
$33
ATIS 0100005.2006 (S2016)
Published Date: 05/01/2007
Auditory Non-Intrusive Quality Estimation Plus (ANIQUE+): Perceptual Model for Non-Intrusive Estimation of Narrowband Speech Quality
$33
ATIS 0100006
Published Date: 05/01/2006
Service Restoration Priority Levels for IP Networks
$18