AWWA ACE59847 PDF

AWWA ACE59847 PDF

Name:
AWWA ACE59847 PDF

Published Date:
06/17/2004

Status:
Active

Description:

"No Concrete" Option Doubles the Kennewick Water Filtration Plant's Capacity - the Submerged Membrane Retrofit Approach

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
awwa-ace59847_1185530

Choose Document Language:
7.20 €
Need Help?
The Water Filtration Plant (WFP) Improvements Project for the City of Kennewick, Washington was initiated to determine the improvements needed to meet the City's anticipated potable water quality and capacity needs. Submerged low-pressure membranes offer a cost-effective "No Concrete" solution to expanding the WFP, which treats Columbia River water in the summertime to supply peak system demands. This 7.5-million-gallons per-day (mgd) plant includes ozone, rapid mix, flocculation, sedimentation, media filtration, and chlorine disinfection. This paper focuses on the approach and key considerations utilized to implement this unique submerged membrane retrofit project. Although pressure membrane systems can be used to retrofit conventional water plants, submerged membrane technology was better suited for Kennewick's needs. Zenon and USFilter/Memcor are the two major suppliers of submerged membrane systems for drinking water. The system designs are different for each supplier and final design depends on the selected system. Membrane system procurement is critical and establishing a fair and protest-proof bidding environment is essential. The criteria for and test conditions of the membrane pilot testing were developed with this in mind. Careful coordination with each vendor was required to understand the filter building retrofit requirements for each system. Some specific examples of system design parameters that impact the filter building retrofit are: membrane basin depth, overhead crane/hoist capacity and lifting height for the membranes, and locating the permeate pumps adjacent to the membrane tanks. Includes 4 references, tables, figures.
Edition : Vol. - No.
File Size : 1 file , 650 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 21
Published : 06/17/2004

History


Related products

AWWA ACE59833
Published Date: 06/17/2004
The Effects of Hollow Fiber Length and Aeration Rate on Filtration Behavior in Submerged Microfiltration
7.20 €
AWWA ACE59852
Published Date: 06/17/2004
Security Practices Primer for Water Utilities
7.20 €
AWWA ACE59884
Published Date: 06/17/2004
Consumer Complaints as Contamination Sentinels
7.20 €
AWWA ACE59915
Published Date: 06/17/2004
Oxidation and Adsorption of Fishy/Swampy/Grassy Odors in Drinking Water
7.20 €

Best-Selling Products

ALI A14.1-2007
Published Date: 08/20/2007
American National Standard (ASC) for Ladders - Wood Safety Requirements
ALI A14.1-2017 Errata 1
Published Date: 10/27/2020
Errata to American National Standard for Ladders - Wood Safety Requirements
ALI A14.1-2017
Published Date: 12/06/2017
American National Standard for Ladders - Wood Safety Requirements, Includes Errata (2020)
82.50 €
ALI A14.11-2018
Published Date: 2018
American National Standard Safety Requirements for Stepstools
82.50 €
ALI A14.3-2008
Published Date: 10/31/2008
American National Standard (ASC) for Ladders - Fixed - Safety Requirements
75.00 €
ALI A14.3-2018
Published Date: 10/12/2018
American National Standard (ASC) for Ladders - Fixed - Safety Requirements
82.50 €