AWWA ACE59903 PDF

AWWA ACE59903 PDF

Name:
AWWA ACE59903 PDF

Published Date:
06/17/2004

Status:
Active

Description:

Walnut Creek Water Treatment Plant Improvements - A Pseudo-Spiral Tank Baffle for Maximum Chlorine Contact Efficiency

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
An effective means of providing a greater level of disinfection without increasing disinfection byproducts is to improve chlorine contact chamber flow characteristics. The question of the most efficient geometric design of a chlorine contact chamber has been studied in the past. A circular basin is more economical than a rectangular basin, but typical baffle wall arrangements are difficult to fit into a circular shape. The most common baffle designs are serpentine patterns or other combinations of straight chambers, which typically achieve disinfection efficiencies (T10/T) of 70% or less. A new spiral baffle design combines the economics of a circular contact chamber with the extremely high disinfection efficiency and low headloss inherent in a spiral baffle wall arrangement. Although spiral baffle designs have been designed and built in the past, the actual construction of a spiral is often mistakenly thought to be difficult. Most previous designs relied on concentric circular walls inside the outer shell, with a radial wall intersecting the concentric circles. This design is essentially a hybrid of a spiral and a serpentine pattern, and although more efficient than a straight-walled serpentine arrangement, the discontinuity of the circular walls due to the gaps along the radial wall make for difficult analysis, and a substantial boundary member. The spiral design was composed entirely of circular semi-circles or partial circles, of varying radii. This eliminated all sharp corners, allowing the water to always flow in circular pattern, thereby considerably reducing turbulence and head losses. By placing the inlet at the edge of the circular tank and the outlet in the center, concerns of cross connection were eliminated. Includes figures.
Edition : Vol. - No.
File Size : 1 file , 810 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 12
Published : 06/17/2004

History


Related products

AWWA ACE59875
Published Date: 06/17/2004
Rapid Screening Assay for Pathogen Detection in Water
$7.2
AWWA ACE59898
Published Date: 06/17/2004
UV System Validation - from City to Nation to State
$7.2
AWWA ACE59900
Published Date: 06/17/2004
Issues Related to the Development of a Virulence Factor Activity Relationships (VFARs) Biochip for Waterborne Pathogens
$7.2
AWWA ACE59913
Published Date: 06/17/2004
Water Security: Implementing Security Measures in a Cost-Effective Manner
$7.2

Best-Selling Products