AWWA ACE61828 PDF

AWWA ACE61828 PDF

Name:
AWWA ACE61828 PDF

Published Date:
06/17/2005

Status:
Active

Description:

To Lift or Boost? Modifying the Operation of an Existing Pump Station to Maximize Energy Efficiency

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
At the Greater Cincinnati Water Works (GCWW), energy management is an important component of operating all pumping facilities. During a recent energy management analyses of a 35 mgd pump station, it was determined that significant energy savings could be achieved if the pumping operation was radically changed. The normal operation of the facility was a "dump and pump" operation, where the water from the upstream distribution system fills the reservoir, and then the water is pumped from the reservoir to the next pressure zone. Because the inlet pressures to the reservoir were significantly higher than anticipated (70 psi versus 20 psi), an innovative solution was developed to convert the pump station from a "dump and pump" operation to a booster pump operation. Extensive hydraulic and economic analyses were performed to determine if the existing pumps could be modified to efficiently operate as booster pumps, thereby lowering the required horsepower usage and capturing significant energy savings. However, the pump's ability to also operate as a lift pump had to be maintained to continue using part of the 2.5 MG storage reservoir for water quality purposes. The hydraulic analyses showed that by carefully trimming the pump impellers, the pumps could be converted to pump efficiently in both the booster mode and the lift mode. The economic analysis showed that the cost of modifying the existing pumps could be recovered with the projected energy savings in less than three years. The long-term electrical savings were estimated at about 20 percent of the current electrical costs. Also, the 70-psi inlet pressure had to be reduced to about 10 psi before entering the reservoir. Throttling the water into the reservoir was causing premature failure of a critical inlet valve and resulted in undesirable pressure fluctuations on the upstream distribution system. In conjunction with the pump modifications, the control valve to the reservoir inlet was replaced with a unique valve called a sleeve valve. Includes tables, figures.
Edition : Vol. - No.
File Size : 1 file , 640 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 8
Published : 06/17/2005

History


Related products

AWWA ACE61653
Published Date: 06/17/2005
Water Quality Modeling to Support Switching to Chloramines: A Case Study
$7.2
AWWA ACE61688
Published Date: 06/17/2005
A New AwwaRF/CEC Research Project: Zero Liquid Discharge for Inland Desalination
$7.2
AWWA ACE61695
Published Date: 06/17/2005
Seattle Maximizes Its Security Investment with a Prudent, Yet Reasonable, Master Plan
$7.2
AWWA ACE61698
Published Date: 06/17/2005
Utilizing Spore Removal to Monitor Plant Performance for Cryptosporidium Removal
$7.2

Best-Selling Products

TAPPI 0109DIRT
Published Date:
Dirt Estimation Chart (Opaque)
$34.5
TAPPI 0109DIRTCAL
Published Date:
Calibrated Size Estimation Chart
TAPPI 0109DIRTT
Published Date:
Size Estimation Chart (Transparency)
$25.2
TAPPI T 1006 sp-06
Published Date: 01/17/2006
Testing of Fiber Glass Mats: Use of Modified TAPPI Prodecures for Sampling and Lot Acceptance, Stiffness, Tear Resistance, Air Permeability, and Thickness
TAPPI T 1006 sp-10
Published Date: 01/01/2010
Testing of Fiber Glass Mats: Use of Modified TAPPI Prodecures for Sampling and Lot Acceptance, Stiffness, Tear Resistance, Air Permeability, and Thickness
$14.7
TAPPI T 1006 sp-15 (R2022)
Published Date: 2014
Testing of Fiber Glass Mats: Use of Modified TAPPI Prodecures for Sampling and Lot Acceptance, Stiffness, Tear Resistance, Air Permeability, and Thickness
$14.7