AWWA ACE63003 PDF

AWWA ACE63003 PDF

Name:
AWWA ACE63003 PDF

Published Date:
06/01/2006

Status:
Active

Description:

High Rating Existing Granular Media Filters - Still a Good Idea?

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
Filtration rate above 4 gpm/sf is still considered "high rate" by most regulators in the United States. The desire to achieve more cost effective filter capacity drives many water utilities to select a filtration rate of 6 gpm/sf or higher, which is typically implemented through up-rating existing filters. Regulatory pressures to provide low turbidity water, and the need to properly handle recycle or discharges of wastewater has placed filter operations under much more scrutiny than 10 or 20 years ago. The decision of high-rating existing filters should also take into consideration more than just effluent turbidity concentrations or particle counts as is commonly done for high rate approvals. The overall operation of the facility should also be considered. This paper reviews some of the key results of water plant high rate studies (in Michigan and North Carolina) for rate increases up to 6 gpm/sf on conventional sand and anthracite dual media filters, with media depths ranging from 24 to 48 inches. The studies showed that during normal operations, the plants were obvious candidates for higher rate filtration, however, from an operations standpoint; the plant(s) performed much differently under high production periods or problematic source (high algae or manganese) water periods. Filter runs, filter to waste periods, washwater handling volumes and facilities, unit filter run volumes (UFRV), and overall plant reliability was discussed in light of both regulatory limits and Partnership for Safe Water goals of 0.10 ntu. Recommendations for review of operational factors outside of simple filter effluent water quality were presented to allow for better assessment of higher filtration rates, and related facility improvements as part of future plant upgrades. Includes tables, figures.
Edition : Vol. - No.
File Size : 1 file , 700 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 11
Published : 06/01/2006

History


Related products

AWWA ACE62972
Published Date: 06/01/2006
Application of HACCP for Distribution System Protection
$7.2
AWWA ACE63004
Published Date: 06/01/2006
Arc Flash in the Water/Wastewater Industry: No Longer an Emerging Issue
$7.2
AWWA ACE63049
Published Date: 06/01/2006
The Effect of Nutrients and Disinfection on Microbial Regrowth during Storage in Domestic Water Heaters
$7.2
AWWA ACE63080
Published Date: 06/01/2006
Perchlorate Reduction by Zero-valent Titanium (TiO)
$7.2

Best-Selling Products

IEEE/CABA Smart Grid Research: Connected Homes
Published Date: 05/17/2013
Impact of Smart Grid on Connected Homes Landmark Research Study
$525