Description:

Coping With Unexpected High Lead Levels

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
During the first round of monitoring for the Lead and Copper Rule, the City of Martinez was surprised by high lead levels. The rule permits water utilities to consider how measures to control corrosion will affect other regulated water quality parameters. All of the corrosion control options called for modified chemical addition following filtration; thus, none would interfere with the primary disinfection process. But, because all the options require altering the finished water's pH, residual disinfection could be affected; this would need to be monitored. Phosphate inhibitor feed would also require a flushing program to remove existing corrosion byproducts in the distribution system. Addition of a zinc orthophosphate could cause problems for wastewater treatment facilities: one uses wetland treatment and the other uses a furnace. Phosphate corrosion inhibitors would cause taste problems during the transition period, especially for customers in older homes with galvanized pipes. Operational reliability would not be a concern for the pH adjustment option, which would require only a small increase in the existing sodium hydroxide feed levels. Of all the options, pH adjustment seems to cause the least problems and also be the least expensive.
File Size : 1 file
ISBN(s) : 0898677149
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 12
Published : 01/01/1993

History


Related products

AWWA ACE93186
Published Date: 01/01/1993
A New Hydraulic Flocculation Process for Water Treatment
$7.2
AWWA ACE93185
Published Date: 01/01/1993
Pilot Plant Comparison of Dissolved Air Flotation and Direct Filtration
$7.2
AWWA ACE93179
Published Date: 01/01/1993
Instrumental Methods for Meeting Rechlorination Requirements
$7.2
AWWA ACE93178
Published Date: 01/01/1993
Fusion Bonded Epoxy for Flow Efficiency and Corrosion Protection of Steel and Ductile Iron Pipe
$7.2

Best-Selling Products

CanGA 1.1-M81 (1996)
Published Date: 01/01/1981
Domestic Gas Ranges
CanGA 1.10-M94
Published Date: 01/01/1994
Gas Food Service Equipment (Baking and Roasting Ovens)
CanGA 1.6-M95
Published Date: 01/01/1995
Outdoor Cooking Gas Appliances
CanGA 1.6a-M97
Published Date: 12/22/1997
Addenda to CanGA 1.6-M95 - Outdoor Cooking Gas Appliances
CanGA 12.2-M92(R1997)
Published Date: 01/01/1992
Propane Fuel System Components for Use on Highway Vehicles
CanGA 12.3-M95
Published Date: 01/01/1995
Fuel System Components for Natural Gas Powered Vehicles