AWWA ACE93157 PDF

AWWA ACE93157 PDF

Name:
AWWA ACE93157 PDF

Published Date:
01/01/1993

Status:
Active

Description:

The C-T Concept and Modifications to Improve Detention Times

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
awwa-ace93157_230751

Choose Document Language:
7.20 €
Need Help?
The Surface Water Treatment Rule requires maintenance of CT (disinfection concentration multiplied by time) through the disinfection process. The CT calculation requires use of T10, which is usually lower than theoretical detention time and is defined as the time in which 10 percent of the water passes through a basin, system, or process in which a disinfectant residual is maintained. If the CT value needs to be increased, there are a number of options: increase "C" by increasing the disinfectant residual; decrease the CT required by using a different disinfectant or lowering the pH; or increase T10 by increasing the minimum depth of the clearwell, lowering high service flow peaks, modifying inlets or outlets, or installing baffles. Of course, each measure must be evaluated for its side-effects on water quality. The results of a study of 20 tracer tests and clearwell modifications are summarized. The study summarized data from four basic clearwell configurations, including single circular and square, and double circular and square clearwells operating in series.
File Size : 1 file
ISBN(s) : 0898677149
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 14
Published : 01/01/1993

History


Related products

AWWA ACE91010
Published Date: 01/01/1991
Mixing Characteristics in Distribution System Storage Reservoirs
7.20 €
AWWA ACE93189
Published Date: 01/01/1993
The Role of Mutagenicity in Determining Drinking Water Quality
7.20 €
AWWA ACE93178
Published Date: 01/01/1993
Fusion Bonded Epoxy for Flow Efficiency and Corrosion Protection of Steel and Ductile Iron Pipe
7.20 €
AWWA ACE93177
Published Date: 01/01/1993
Recent Advances in Pulsed Sludge Blanket Clarifiers
7.20 €

Best-Selling Products

SN-CEN ISO/TR 10400:2011
Published Date: 02/09/2011
Petroleum and natural gas industries — Equations and calculations for the properties of casing, tubing, drill pipe and line pipe used as casing or tubing (ISO/TR 10400:2007)
SN-CEN ISO/TR 10400:2021
Published Date: 10/25/2021
Petroleum and natural gas industries — Formulae and calculations for the properties of casing, tubing, drill pipe and line pipe used as casing or tubing (ISO/TR 10400:2018)
SN-CEN ISO/TR 11064-10:2022
Published Date: 05/25/2022
Ergonomic design of control centres - Part 10: Introduction to the control room design series of standards (ISO/TR 11064-10:2020)
SN-CEN ISO/TR 11594:2022
Published Date: 12/02/2022
Best practices for the creation/evaluation of fingerprint analysis in accordance with the ISO 28199 series (ISO/TR 11594:2022)
SN-CEN ISO/TR 11610:2004
Published Date: 04/15/2004
Protective clothing — Vocabulary (ISO/TR 11610:2004)
SN-CEN ISO/TR 11811:2012
Published Date: 08/15/2012
Nanotechnologies — Guidance on methods for nano- and microtribology measurements (ISO/TR 11811:2012)