AWWA ACE94200 PDF

AWWA ACE94200 PDF

Name:
AWWA ACE94200 PDF

Published Date:
01/01/1994

Status:
Active

Description:

Enhanced Coagulation: Impacts on Residual Management Programs

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
awwa-ace94200_230966

Choose Document Language:
7.20 €
Need Help?
In addition to the future requirements for enhanced coagulation, some systems may benefit from increasing coagulant dose beyond that required by the D/DBP Rule. For example, systems with high raw water TOC levels may further reduce regrowth potential in the distribution system by increasing coagulant dose beyond future requirements. In general, the optimal pH for TOC removal is in the range of 5.5 to 6.0 with alum coagulant dosages ranging from 5 to 10 mg ferric coagulant/mg of TOC. The nature and concentration of NOM will dictate the treatment process adopted, especially the coagulant type and dose, polymer type and dose, and oxidant type and dose. Higher coagulant dosages can significantly increase sludge volume and quality that need to be treated prior to disposal. Because of the possible adverse impacts to existing residuals management programs from enhanced and optimized coagulation to further reduce distribution system regrowth potential and DBP formation potential, it is essential that quantitative and qualitative assessments of future residuals production be made prior to the implementation of any increase in coagulant dose.
File Size : 1 file
ISBN(s) : 0898677750
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 20
Published : 01/01/1994

History


Related products

AWWA ACE94234
Published Date: 01/01/1994
Evaluation of the H2O2/Vis-UV Advanced Oxidation Process for Controlling DBP Precursors and Providing Disinfection for Small Systems
7.20 €
AWWA ACE94230
Published Date: 01/01/1994
Pilot Testing and Design of North Carolina's First Biological Activated Carbon Facility
7.20 €
AWWA ACE94211
Published Date: 01/01/1994
Evaluation of Cryptosporidium Removal Through High-Rate Filtration
7.20 €
AWWA ACE94209
Published Date: 01/01/1994
Giardia and Cryptosporidium Cysts Removal Through Direct Filtration and Conventional Treatment
7.20 €

Best-Selling Products

IEEE/ANSI 101-1987
Published Date: 12/31/1988
IEEE Guide for the Statistical Analysis of Thermal Life Test Data
67.20 €
IEEE/ANSI 18-1980
Published Date: 12/15/1980
IEEE Standard for Shunt Power Capacitors
23.40 €
IEEE/ANSI 213-1961
Published Date: 04/06/1961
ANSI/IEEE Radio Interference: Methods of Measurement of Conducted Interference Output to the Power Line from FM and Television Broadcast Receivers in the Range of 300 kHz to 25 MHz
16.50 €
IEEE/ANSI 262-1968
Published Date: 1968
USA Standard Test Code for Distribution, Power and Regulating Transformers, and Shunt Reactors
19.50 €
IEEE/ANSI 315-1975
Published Date: 12/29/1975
IEEE Standard for Graphic Symbols for Electrical and Electronics Diagrams (Including Reference Designation Letters)
39.90 €
IEEE/ANSI 315A-1986
Published Date: 09/12/1986
American National Standard - Supplement to Graphic Symbols for Electrical and Electronics Diagrams
12.90 €