AWWA ACE95288 PDF

AWWA ACE95288 PDF

Name:
AWWA ACE95288 PDF

Published Date:
01/01/1995

Status:
Active

Description:

Modeling of THM in Water Distribution Systems - Charlotte Mecklenburg Utility Department

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
Like many surface water users, Charlotte Mecklenburg Utility Department (CMUD) is concerned with the water quality changes ultimately seen in its water as it progresses through treatment into the distribution system and finally to the customer's tap. Trihalomethane (THM) formation, in particular, is an inherent problem seen in distributions systems employing surface water sources. Also of concern is the accompanying decay of chlorine residual seen in high THM formation potential water. There are three areas at which CMUD can take measures to control THM formation. The first is at the water supply. Watershed management and protection techniques can be employed to control the presence of the organic precursors needed for THM formation. The second area is at the treatment plant. Treatment processes resulting in more efficient precursor removal and/or modification of disinfection practices can be implemented. The final area is in the distribution system. CMUD has been utilizing computer hydraulic models to analyze its distribution system. They had been able to size distribution water mains to meet future system demands, but were unable to determine how water quality would be affected by future changes. CMUD needed a tool to help identify possible water quality problems in the system. With the upcoming changes in the drinking water regulations, CMUD felt there was a great need to have the capability to better look at water quality parameters. In 1993 Boyle Engineering began work on a Water Master Plan for the Department. This many faceted study included hydraulic distribution system modeling, water quality distribution modeling, surge modeling and integration of a facility management system including GIS integration. The water quality modeling would be based on the hydraulic model of the water mains sized 12-inch and larger. Although the accuracy of the water quality model would be a satisfactory first step for establishing trends and determining general problem areas.
File Size : 1 file
ISBN(s) : 089867834X
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 10
Published : 01/01/1995

History


Related products

AWWA ACE95290
Published Date: 01/01/1995
An Evaluation of Ion Exchange Softening on the Leaching of Metals From Households Plumbing Materials
$7.2
AWWA ACE95283
Published Date: 01/01/1995
Establishing NPDES Limitations for Residuals From Three Phoenix Water Treatment Plants
$7.2
AWWA ACE95272
Published Date: 01/01/1995
Removal of Natural Organic Matter With Anion Exchange Resins
$7.2
AWWA ACE95262
Published Date: 01/01/1995
Small, Inexpensive Systems Using Diatomaceous Earth Filtration to Comply With the SWTR
$7.2

Best-Selling Products

UNE-CLC/TR 50373:2006 IN
Published Date: 06/07/2006
Wind turbines - Electromagnetic compatibility
UNE-CLC/TR 50453:2008 IN
Published Date: 11/26/2008
Evaluation of electromagnetic fields around power transformers
UNE-CLC/TR 50462:2009
Published Date: 10/14/2009
Rules for the determination of uncertainties in the measurement of the losses on power transformer and reactors
UNE-CLC/TR 50488:2007 IN
Published Date: 07/18/2007
Railway applications - Safety measures for the personnel working on or near overhead contact lines