AWWA ACE99573 PDF

AWWA ACE99573 PDF

Name:
AWWA ACE99573 PDF

Published Date:
01/01/1999

Status:
Active

Description:

Balancing Environmental and Potable Water Quality Needs in Indirect Potable Reuse Projects

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The City of West Palm Beach, Florida (City), in conjunction with Palm Beach County, operated a Demonstration Project over a one-year period to provide cost and performance data for treatment of secondary wastewater effluent to indirect potable reuse standards. The City utilized an Advance Wastewater Treatment (AWT) Plant that used a solids contact clarifier (SCC) and a deep bed denitrification filter (DNF) followed by chlorine disinfection and wetlands polishing. For the West Palm Beach Wetlands Based Water Reclamation Project, it is anticipated that the treated effluent will be routed to natural receiving wetlands that recharge the surficial aquifer in the vicinity of water supply wells. For this reason, the quality of the effluent was evaluated for compliance with Class III water quality standards and wetlands antidegradation requirements. Over the first year of operation, the AWT effluent occasionally exhibited elevated iron levels in excess of the Class III Surface Water Quality Standard of 1.0 mg/l. In addition the effluent total phosphorus concentrations were well in excess of the concentrations exhibited in the potential receiving wetlands. Such iron and phosphorus concentrations in the AWT effluent could prevent or severely restrict the application of the reclaimed water to the wetlands without the addition of new unit processes. During operation of the Demonstration Project, several characteristics of the treatment process were observed that were potentially related to the excessive iron and phosphorus concentration in the AWT effluent. Based upon the AWT Plant water quality and process observations, two actions were deemed necessary to optimize the coagulation/flocculation/sedimentation process: optimize the coagulation and flocculation step including coagulation type, coagulation dosage, and pH condition during coagulation as well as determine the need for a coagulation/flocculation aid polymer and necessary polymer dosage; and, minimize the potential for biological growth in the secondary effluent transmission main, INF, and SCC.
File Size : 1 file , 200 KB
ISBN(s) : 1583210016
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 16
Published : 01/01/1999

History


Related products

AWWA ACE99366
Published Date: 01/01/1999
Performance of a Conventional Surface Water Plant Using Mixed-Oxidants for Microflocculation and Final Disinfection
$7.2
AWWA ACE99374
Published Date: 01/01/1999
Alexis WTP Upgrade Project (SCADA - When You Can't Be Two Places at Once)
$7.2
AWWA ACE99449
Published Date: 01/01/1999
Fuel Oxygenate Health Issues
$7.2
AWWA ACE99506
Published Date: 01/01/1999
Impact of Temperature on Biofilter Performance and Microbial Community Structure
$7.2

Best-Selling Products

CIMA AP-0802
Published Date: 01/01/2008
AERIAL PLATFORM SAFETY MANUAL
$1.8
CIMA ASP-0806
Published Date: 01/01/2008
Asphalt Paver Safety Manual
$1.2
CIMA AT03-01
Published Date: 01/01/2005
AGRICULTURAL TRACTOR SAFETY MANUAL
$1.8
CIMA BL02-08
Published Date: 01/01/2018
Backhoe Loader Safety Manual
$2.1
CIMA BL02-08
Published Date: 01/01/2011
BACKHOE LOADER SAFETY MANUAL
CIMA C-70-2
Published Date: 01/01/2014
Mobile Crane Safety Manual