AWWA CSC91085 PDF

AWWA CSC91085 PDF

Name:
AWWA CSC91085 PDF

Published Date:
01/01/1991

Status:
Active

Description:

Distributed Filter Controls Improve Treatment Performance

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
Westpac Utilities, Reno, Nevada, recently upgraded controls on eight filters. This paper describes the new control system and process of implementation in detail. Westpac had a very limited budget and had to keep the plant in operation during construction. For these reasons, Westpac acted as purchaser and prime contractor on the job. The author provides background on existing filter flow controls, backwash controls, and performance monitoring. The design approach and constraints are detailed. Also discussed in some detail are the filter backwash process, including initiation and sequencing. Low-lift pump controls, new sensors, the computer system, training, and construction are briefly discussed. Several start-up problems occurred, resulting from confusion between design directives and desires of the operating staff, lack of training, lack of participation by technicians in the start-up phase, geographic distance between various people working on the project, and commercial software that contained bugs.
File Size : 1 file
ISBN(s) : 0898675812
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 20
Published : 01/01/1991

History


Related products

AWWA CSC91093
Published Date: 01/01/1991
The Need for Integration of Personal Computers in Your Water SCADA System
$7.2
AWWA CSC91083
Published Date: 01/01/1991
Computer Data Communications Media and Methods
$7.2
AWWA CSC91077
Published Date: 01/01/1991
Water Treatment Plant Implements Automatic Filter Backwash
$7.2
AWWA CSC91070
Published Date: 01/01/1991
Personal Computers in the Laboratory
$7.2

Best-Selling Products

AHRI 1010-94
Published Date: 01/01/1994
Self-Contained, Mechanically Refrigerated Drinking-Water Coolers
$7.5
AHRI 1060-00
Published Date: 01/01/2000
Rating Air-to-Air Energy Recovery Ventilation Equipment
$13.5
AHRI 1060-01
Published Date: 09/01/2001
Rating Air-to-Air Heat Exchangers for Energy Recovery Ventilation Equipment
$8.7
AHRI 1060-2005
Published Date: 2005
Performance Rating of Air-To-Air Heat Exchangers for Energy Recovery Ventilation Heat Equipment
$6.9
AHRI 1060-2011
Published Date: 2011
Performance Rating of Air-To-Air Heat Exchangers for Energy Recovery Ventilation Heat Equipment (I-P) (AHRI)
$6.9
AHRI 1060-2013
Published Date: 2013
Performance Rating of Air-To-Air Heat Exchangers for Energy Recovery Ventilation Heat Equipment (I-P) (AHRI)
$6.9