Description:

Linking Hydraulic Network Models and SCADA Systems: The ABCs of System Integration

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
An integrated package has been developed for the City of Plano, Texas, consisting of a combined hydraulic simulation model and a SCADA system. The integrated system is part of a larger control model which is used by Plano system operators to control operating costs, utilize state of the art control and telemetry equipment, and improve overall operations. Information describing tank levels and pump characteristics for a 24-hour period is gathered and stored by the SCADA system. This information is written to a file with a specific format. The control model copies the file from the SCADA system, extracts data on tank levels and pump performance, and writes this information to a KYPIPE-compatible data file. The control model also uses SCADA collected data in a mass-balance scheme to determine short-term demand forecasts. The advantage of using an integrated system such as the one described in this paper is that it eliminates the need for system operators to make bothersome changes to a hydraulic model in order to analyze a scenario. Instead, operators are able to focus on the results of the simulation. When used within the framework of a control model, operators can initiate a simulation to develop efficient operating policies without worrying how data is transferred from one system to another.
File Size : 1 file
ISBN(s) : 0898677343
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 9
Published : 01/01/1994

History


Related products

AWWA CSC94033
Published Date: 01/01/1994
GIS Environment Implementation of Maintenance Management and Hydraulic Modeling Applications
$7.2
AWWA CSC94047
Published Date: 01/01/1994
Integrating a Network Model With an Expert System
$7.2
AWWA CSC94025
Published Date: 01/01/1994
Estimate of Water Conservation Achieved in Las Vegas
$7.2
AWWA CSC94013
Published Date: 01/01/1994
Open Systems - Concept or Reality?
$7.2

Best-Selling Products

UNE-IEC/TR 60865-2:2006 IN
Published Date: 04/26/2006
Short-circuit currents - Calculation of effects - Part 2: Examples of calculation.
UNE-IEC/TR 60893-4:2005
Published Date: 02/09/2005
Insulating materials - Industrial rigid laminated sheets based on thermosetting resins for electrical purposes - Part 4: Typical values
UNE-IEC/TR 60909-2:2010 IN
Published Date: 02/17/2010
Short-circuit currents in three-phase a.c. systems - Part 2: Data of electrical equipment for short-circuit current calculations.
UNE-IEC/TR 61000-2-8:2006 IN
Published Date: 06/28/2006
Electromagnetic compatibility (EMC) - Part 2-8: Environment - Voltage dips and short interruptions on public electric power supply systems with statistical measurement results (IEC/TR 61000-2-8:2002)
UNE-IEC/TR 61000-3-6:2006 IN
Published Date: 07/19/2006
Electromagnetic compatibility (EMC) - Part 3: Limits - Section 6: Assessment of emission limits for distorting loads in MV and HV power systems - Basic EMC publication (IEC/TR 61000-3-6:1996)
UNE-IEC/TR 61010-3:2006 IN
Published Date: 03/15/2006
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3: Protocol for the preparation of conformity verification reports for the IEC 61010 2nd edition series .