AWWA INF52165 PDF

AWWA INF52165 PDF

Name:
AWWA INF52165 PDF

Published Date:
01/01/2000

Status:
Active

Description:

66 MG Twin Oaks Reservoir: Planning/Design/Construction

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The Vallecitos Water District (District) located in northern San Diego County, California, operates a highly efficient water infrastructure system consisting of pumping, storage, transmission, and disinfection facilities. VWD is a rapidly growing district providing water service to over 15,000 customers. Currently, the District is experiencing rapid growth which necessitates the expansion of the District's infrastructure. The need for a reservoir was driven by two conditions: a State of California, Department of Health Services directive to cover or abandon an existing open Twin Oaks Reservoir; and the need to provide additional operational and emergency storage to meet rapidly growing demands. The District is also entirely dependent on imported potable water. The additional storage would help enable the District to provide water service in the event of a disruption in the water supply due to disaster or scheduled maintenance shutdowns. The District prepared a Master Plan in 1991 that recommended a 52 million gallon (mg) water storage facility at the Twin Oaks Reservoir site. The 66mg Twin Oaks reservoir consists of twin 33mg circular pre-stressed tanks. Construction of the first tank was completed in September 1999. The second tank is planned in 5 to 7 seven years or when water demands require it. The construction of the first tank is believed to be the largest structure of its kind within the United States. Due to the size of the reservoir, special considerations were taken into account during the planning, design, and construction of the facility.
Edition : Vol. - No.
File Size : 1 file , 110 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 4
Published : 01/01/2000

History


Related products

AWWA INF52171
Published Date: 01/01/2000
Maintaining Water Pipeline Integrity
$7.2
AWWA INF52174
Published Date: 01/01/2000
Field Performance Monitoring of a Sliplined Watermain
$7.2
AWWA INF52172
Published Date: 01/01/2000
Evaluating the Condition of Existing Water Mains
$7.2
AWWA INF52146
Published Date: 01/01/2000
Water Infrastructure Management: An Overview of European Models and Databases
$7.2

Best-Selling Products

SN-CEN/CLC/TR 14060:2014
Published Date: 12/03/2014
Medical device traceability enabled by unique device identification (UDI)
SN-CEN/CLC/TR 16103:2010
Published Date: 05/12/2010
Energy management and energy efficiency — Glossary of terms
SN-CEN/CLC/TR 16567:2013
Published Date: 09/18/2013
Energy Efficiency Obligation Schemes in Europe — Overview and analysis of main features and possibilities for harmonisation
SN-CEN/CLC/TR 16832:2015
Published Date: 04/24/2015
Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
SN-CEN/CLC/TR 17602-70-23:2021
Published Date: 11/24/2021
Space product assurance — Materials, mechanical parts and processes obsolescence management handbook
SN-CEN/CLC/TR 17602-80-01:2021
Published Date: 11/24/2021
Space product assurance — Reuse of existing software