AWWA INF53983 PDF

AWWA INF53983 PDF

Name:
AWWA INF53983 PDF

Published Date:
06/01/2001

Status:
Active

Description:

The Capabilities and Environmental Benefits of Pneumatic Pipe Bursting in Water Main and Service Line Replacement

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The success rate of pipe bursting in challenging situationshas increased dramatically over the past few years. Much has been learned aboutthe capabilities of the method as well as what is needed for the method tosucceed under a wide range of conditions. Pipe bursting potable water lines hasgained national attention with several large-scale water main replacementprojects recently completed. The use of guide head (schnozz) technology has alsomade pipe bursting an effective method for replacing small-diameter lines. Theproduct pipe, zero-leak High Density Polyethylene Pipe (HDPE), can helpmunicipalities limit the amount of potable water lost to system leakage.Pneumatic tools can burst fracturable pipes (cast iron, asbestos cement,reinforced concrete, vitrified clay, non-reinforced concrete, PVC, reinforcedplastic mortar (RPM), ABS and some other plastics) with diameters between 4 and54 inches. In the bursting procedure, a pneumatic tool is placed into the hostpipe at an entry pit or manhole. A winch line, based at the exit area pit andattached to the head of the tool, guides it through the host pipe. Continuouspercussion from the pneumatic tool fractures the host pipe. The tool effectivelyhammers its way through, forcing the fragments into the surrounding soil, whilepulling the new pipe into place behind it. Several factors dictate whether pipebursting is appropriate for the replacement of a failed line. Theseconsiderations include: host pipe material, diameter, condition, depth, andlength; new pipe diameter requirements; working pressure; soil conditions;location of peripheral utilities; and, number of service connections. This paperpresents examples of several projects that have used pipe bursting to replacewater mains and service lines.
Edition : Vol. - No.
File Size : 1 file , 140 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 8
Published : 06/01/2001

History


Related products

AWWA INF53951
Published Date: 05/01/2001
Creating an Asset Management Strategy: An Asset Management Template
$7.2
AWWA INF54002
Published Date: 06/01/2001
East Bay Municipal Utility District: Water System Operations and Technical Manual Project
$7.2
AWWA INF53998
Published Date: 06/01/2001
Innovative Designs for the Management of ASR Water Quality at a Potable Water Supply Facility
$7.2
AWWA INF53991
Published Date: 06/01/2001
San Francisco Water Department Reservoir Upgrade Program
$7.2

Best-Selling Products

IEEE/IEC 1249-2013
Published Date: 09/27/2013
IEC/IEEE Guide for Computer-based Control for Hydroelectric Power Plant Automation
$59.1
IEEE/IEC 60076-21-2011
Published Date: 12/11/2011
Power Transformers - Part 21: Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators
$85.8
IEEE/IEC 60214-2-2019
Published Date: 06/14/2019
IEEE/IEC International Standard for TAP-changers --Part 2: Application guidelines
$31.8
IEEE/IEC 60488-1-2004
Published Date: 11/22/2004
IEC/IEEE International Standard - Higher Performance Protocol for the Standard Digital Interface for Programmable Instrumentation - Part 1: General
$117.3
IEEE/IEC 60488-2-2004
Published Date: 05/15/2004
IEC/IEEE International - Standard Digital Interface for Programmable Instrumentation - Part 2: Codes, formats, protocols and common commands
$111.9
IEEE/IEC 60980-344-2020
Published Date: 10/19/2020
IEEE/IEC International Standard - Nuclear facilities - Equipment important to safety - Seismic qualification
$30.3