Description:

Journal AWWA - Coliforms in a Water Distribution System: A Remedial Approach

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$9
Need Help?
In 1982 the incidence of noncoliform colonies increased alarmingly in the standard membrane filter tests of samples from the Springfield, Illinois system. This signaled a potential problem with bacteria and was followed by coliform infestation in the water mains. Intensive measures were taken to control bacterial growth in the water treatment process and in the distribution system, with an ultimate goal of preventing the reseeding of the system by chlorine-resistant organisms. This paper discusses action taken to eliminate this problem, including: chlorine application to incoming raw water; use of iron coagulant; discontinuation of ammonia feed; addition of potassium permanganate to mixing basin; increased feed rate of lime; flushing of the distribution system for eight days; and sample monitoring. Includes 17 references, tables, figures.
Edition : Vol. 75 - No. 11
File Size : 1 file , 1.7 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 5
Published : 11/01/1983

History


Related products

AWWA JAW10538
Published Date: 11/01/1983
Journal AWWA - Telemetric Control of Water Distribution Systems
$9
AWWA JAW10540
Published Date: 11/01/1983
Journal AWWA - The Effect of Upstream Piping on Swing-Check Valves
$9
AWWA JAW10541
Published Date: 11/01/1983
Journal AWWA - Maintaining Distribution System Valves
$9
AWWA JAW10542
Published Date: 11/01/1983
Journal AWWA - Check Valves With Brains
$9

Best-Selling Products

JOTP JOTP-001
Published Date: 01/08/2013
Allied Ammunition Safety and Suitability for Service Assessment Testing Publication - Guidance
$7.2
JOTP JOTP-010
Published Date: 01/08/2013
Safety and Suitability for Service Assessment Testing for Shoulder Launched Munitions
$18
JOTP JOTP-010A
Published Date: 11/07/2014
Safety and Suitability for Service Assessment Testing for Shoulder Launched Munitions
$18
JOTP JOTP-010B
Published Date: 05/09/2016
Safety and Suitability for Service Assessment Testing for Shoulder Launched Munitions
$18
JOTP JOTP-011
Published Date: 12/05/2014
Safety and Suitability for Service Assessment Testing for Surface and Underwater Launched Munitions
$18
JOTP JOTP-012
Published Date: 07/01/2013
Safety and Suitability for Service Assessment Testing for Aircraft Launched Munitions
$18