AWWA MTC50295 PDF

AWWA MTC50295 PDF

Name:
AWWA MTC50295 PDF

Published Date:
01/01/1999

Status:
Active

Description:

Insights on Recent Membrane Integrity Testing of an Organic Selective Nanofiltration & Hybrid Membrane Arrangement

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
This paper reports on a major study conducted from August 1996 through April 1997 by Irvine Ranch Water District (IRWD) evaluating the performance of an integrated membrane system with multi-objectives including organic and disinfection byproduct precursor removal, pathogen and virus removal, and biological stabilization. Prior to initiating the membrane pilot study, four different membrane integrity tests were performed. Membrane integrity tests were conducted to verify that leakage across the organic selective-nanofiltration (NF) membrane elements and the NF process components such as end seals, spacers and O-rings was not occurring. These methods included: visual inspection and probing by dye testing, EC and UV 254 rejection; vacuum testing (post pilot tested); bacteriological (E-Coli tracer study); and, particle counting. The probe test using a methyl violet dye proved unsuccessful for the NF membranes tested due to extreme fouling apparently caused by selective removal that resulted in shut down of the membrane process. Electrical conductivity (EC) and UV 254 rejection were not sensitive to predict membrane process integrity for the water tested while vacuum testing verified the failure of several elements, but is limited to pre-testing of the elements off-line and major membrane element defects. Batch particle counting results were inconclusive due to excessive sensitivity for dissolved gas microbubbles. Includes 8 references, tables, figures.
Edition : Vol. - No.
File Size : 1 file , 590 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Published : 01/01/1999

History


Related products

AWWA MTC50314
Published Date: 01/01/1999
Membrane Selection: From Pilot-Scale Evaluation to Preparation of Bid Documents
$7.2
AWWA MTC50313
Published Date: 01/01/1999
Micro- and Ultrafiltration for the Treatment of Surface Water in the Netherlands: Results of Pilot Studies
$7.2
AWWA MTC50310
Published Date: 01/01/1999
Selection of a Nitrate Removal Process for the City of Seymour, Texas
$7.2
AWWA MTC50282
Published Date: 01/01/1999
Development of an Innovative Method to Monitor the Integrity of a Membrane Water Repurification System
$7.2

Best-Selling Products

Modern Drafting Practices & Standards Manual
Published Date: 01/01/1994
$122.7