AWWA QTC97177 PDF

AWWA QTC97177 PDF

Name:
AWWA QTC97177 PDF

Published Date:
01/01/1997

Status:
Active

Description:

In-Situ Water Main Biological Study in New York City: A Study of Distribution System Biofilm Utilizing High Velocity Flushing

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
awwa-qtc97177_228040

Choose Document Language:
7.20 €
Need Help?
In the summers of 1993 and 1994, New York City experienced a series of positive total coliform and E. coli findings in its water distribution systems. A preliminary investigation indicated that several factors could have contributed to these occurrences. These factors included: the substantial increases in water usage during the hot summer months which disturbed the sediments in Hillview Reservoir; waterfowl in the reservoir; and, biofilm activity in the distribution system. To investigate the possibility that biofilm was a significant cause of the coliform and E. coli findings, the City Department of Environmental Protection established a biofilm high velocity flushing project in 1995. This paper presents the results of the two-year project which included field sampling and testing, and laboratory analysis for a broad spectrum of microbial and chemical parameters. The aims of the study were to determine if total coliforms and E. coli could be recovered from the distribution system biofilm using high velocity flushing and to determine the relationship between coliform findings in routine bacterial compliance sampling and high velocity flushing sampling.
File Size : 1 file
ISBN(s) : 0898679583
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 15
Published : 01/01/1997

History


Related products

AWWA QTC97209
Published Date: 01/01/1997
Evaluating the Benefits of a Reliable Groundwater System
7.20 €
AWWA QTC97207
Published Date: 01/01/1997
Nutrients and Biological Filtration in Drinking Water Treatment
7.20 €
AWWA QTC97181
Published Date: 01/01/1997
Direct Biofilm Measurement in Potable Water: An Evaluation of the Bacterial Regrowth Risk in Distribution Systems
7.20 €
AWWA QTC97119
Published Date: 01/01/1997
Laser Scanning Device for Detecting Cryptosporidium
7.20 €

Best-Selling Products

3A 00-00
Published Date: 09/08/2014
3-A Sanitary Standards for General Requirements
3A 00-01-2018
Published Date: 02/01/2018
3-A Sanitary Standard for General Requirements
105.00 €
3A 00-01
Published Date: 06/05/2017
3-A Sanitary Standard for General Requirements
3A 01-08
Published Date: 11/20/2001
Storage Tanks for Milk and Milk Products
3A 01-09
Published Date: 11/19/2013
Insulated Tanks
59.70 €
3A 02-09
Published Date: 11/01/1996
Centrifugal and Positive Rotary Pumps for Milk and Milk Products