AWWA SOURCES59143 PDF

AWWA SOURCES59143 PDF

Name:
AWWA SOURCES59143 PDF

Published Date:
01/11/2004

Status:
Active

Description:

Saving Water While Conserving Energy: Initiatives for ICI Customers - The "Now You Are Talking" Initiatives

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
Most ICI customers find initiatives that save water and conserve energy more attractive than initiatives that save water alone. Initiatives that do both typically have shorter pay back periods. Frequently, there are energy rebates available to further offset the costs, and equipment retrofits usually involve standard, off-the shelf technologies, instead of the detailed engineering evaluations required by recycling/reuse projects. Consequently, initiatives that save water and energy may provide excellent opportunities for water efficiency programs to promote conservation. Measures that increase the evaporative transfer efficiency also save water by reducing evaporation losses. This paper discusses the application of variable speed drives (VSD) in cooling tower fans to improve evaporative transfer efficiency and increase overall energy efficiency. The paper also presents proposed Code changes in the States of California and Oregon to further the implementation of VSDs at new facilities, as well as the economic advantages of retrofitting existing cooling towers with energy and water efficient equipment. The paper also presents a case study that reports ICI customers' comments and experiences regarding implementation of cooling tower water/energy initiatives. Advantages associated with the use of VSDs in cooling towers include: energy consumption reduction up to 75% for the same heat rejection capacity; water consumption reduction up to 25%, without increasing the number of concentration cycles; elimination of splash-out water losses due to the fans frequently being turned off and on; virtual elimination of mechanical shock and noise pollution issues; and, steady cooling tower temperatures, which produce additional energy savings at the plant's chiller equipment. Includes figures.
Edition : Vol. - No.
File Size : 1 file , 330 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 12
Published : 01/11/2004

History


Related products

AWWA SOURCES59148
Published Date: 01/11/2004
Leakage Reduction, A Proven Alternative Resource: A Yorkshire Water Services UK 3-Year Case Study
$7.2
AWWA SOURCES59182
Published Date: 01/11/2004
Getting it Right with the Big Guys: A Case Study in Working Effectively with a Large CII Customer
$7.2
AWWA SOURCES59184
Published Date: 01/11/2004
Counting the Savings: A Water Savings Calculation Model for California's BMPs
$7.2
AWWA SOURCES59185
Published Date: 01/11/2004
Urban Water Use in California: How Much Water Do We Really Need?
$7.2

Best-Selling Products

ULC 101
Published Date: 07/01/2007
Standard Methods of Fire Endurance Tests of Building Construction and Materials
ULC 101
Published Date: 06/01/2014
Standard Methods of Fire Endurance Tests of Building Construction and Materials (CAN/ULC S101-14)
$77.1
ULC 102.2
Published Date: 06/01/2018
Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies
$75
ULC 102.3
Published Date: 01/01/1982
Standard Method of Fire Test of Light Diffusers and Lenses (CAN/ULC S102.3-07)
ULC 102.4
Published Date: 07/01/2010
Standard Method of Test for Fire and Smoke Characteristics of Electrical Wiring, Cables and Non-Metallic Raceways (CAN/ULC S102.4-10)
$52.8
ULC 109
Published Date: 09/01/2014
Flame Tests of Flame Resistant Fabrics and Films (CAN/ULC S109-14)
$61.5