Description:

Solving Plant Siting and Water Quality Issues With High Rate Actiflo Clarification

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
In 1996, the Jordan Valley Water Conservancy District hired Carollo Engineers to study the alternative processes that would allow the District to better utilize this raw water source. The District had the following objectives as it considered various alternatives: to effectively treat the available raw water; to interface efficiently with the existing processes at Southeast Regional Water Treatment Plant to provide an effective overall treatment process; to fit into the existing site and preserve area for possible future new treatment processes (e.g., ozone contactors, additional filters for 30 MGD capacity, etc.); and, to qualify as "conventional treatment plant" for log removal credit under the Surface Water Treatment Rule. Includes tables.
Edition : Vol. - No.
File Size : 1 file , 220 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Published : 01/01/1999

History


Related products

AWWA WQTC50518
Published Date: 01/01/1999
Integrated Optimization of Bromate Formation and Cryptosporidium parvum Oocyst Control in Batch and Flow-Through Ozone Contactors
$7.2
AWWA WQTC50501
Published Date: 01/01/1999
Arsenic Removal - Defining the Characteristics of Arsenic During Water Treatment
$7.2
AWWA WQTC50489
Published Date: 01/01/1999
Biological Manganese Removal for a 26 mgd Water Treatment Plant
$7.2
AWWA WQTC50450
Published Date: 01/01/1999
Interlaboratory Validation of an Ion Chromatographic Method for the Analysis of DBP Anions in Drinking Water
$7.2

Best-Selling Products

CLSI AUTO01-A
Published Date: 12/20/2000
Laboratory Automation: Specimen Container/Specimen Carrier; Approved Standard, AUTO01AE
$54
CLSI AUTO02-A2
Published Date: 01/05/2006
Laboratory Automation: Bar Codes for Specimen Container Identification; Approved Standard, AUTO02A2E
$54
CLSI AUTO03-A2
Published Date: 09/01/2009
Laboratory Automation: Communications with Automated Clinical Laboratory Systems, Instruments, Devices, and Information Systems; Approved Standard, Second Edition, AUTO03A2
$54
CLSI AUTO04-A
Published Date: 03/20/2001
Laboratory Automation: Systems Operational Requirements, Characteristics, and Information Elements; Approved Standard, AUTO04AE
CLSI AUTO05-A
Published Date: 03/20/2001
Laboratory Automation: Electromechanical Interfaces; Approved Standard, AUTO05AE
CLSI AUTO07-A
Published Date: 06/20/2004
Laboratory Automation: Data Content for Specimen Identification; Approved Standard, AUTO07AE