AWWA WQTC53006 PDF

AWWA WQTC53006 PDF

Name:
AWWA WQTC53006 PDF

Published Date:
01/01/2000

Status:
Active

Description:

Water Quality Improvements Resulting From MWRA's Lead and Copper Corrosion Control Program

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
Massachusetts Water Resources Authority (MWRA) provides water to Bostonand 42 other communities in eastern and central Massachusetts. The water is generally of very high quality, although its naturally low pH and alkalinity make it quite corrosive. Based on 2 rounds of sampling conducted in 1992 for worst-case tap water samples collected as per US EPA standards, it was found that 47% of these samples exceededthe Lead and Copper Rule (LCR) Lead Action Level of 0.015 mg/L. Copper was found to be below the action level. This paper describes MWRA's Lead and Copper Corrosion Control Program which involved raising the pH to 9.0 and the alkalinity to 30 mg/L. During the course of the Program there have been a number of water quality improvements in the distribution system which are also discussed. Includes figures.
Edition : Vol. - No.
File Size : 1 file , 350 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 10
Published : 01/01/2000

History


Related products

AWWA WQTC52807
Published Date: 01/01/2000
Development of a Rapid System for Monitoring Total Microbial Load (HPC) in Distribution Systems and Raw Waters
$7.2
AWWA WQTC52875
Published Date: 01/01/2000
Low Pressure UV Inactivation of Cryptosporidium parvum and Giardia lamblia Based on Infectivity Assays and DNA Repair of UV-Irradiated Cryptosporidium parvum Oocysts
$7.2
AWWA WQTC52978
Published Date: 01/01/2000
Use of Recirculating Ozone/Hydrogen Peroxide Combined With Biological Fluidized Bed Treatment System for the Removal of Disinfection By-Products
$7.2
AWWA WQTC52897
Published Date: 01/01/2000
Identification of the Causes for Coliforms and Water Quality Complaints in Distribution Systems: An Event-Based Approach
$7.2

Best-Selling Products

NR 5002881/R/71310/001 ISSUE 4
Published Date: 04/01/2004
Standard Brickwork & Masonry Repair Details - Approval in Principle
$24.3
NR 656JRM02 ISSUE 1.2
Published Date: 09/13/2000
PC-BASED ISM TERMINAL HARDWARE SPECIFICATION
$7.5
NR 656JRM03 ISSUE 1.1
Published Date: 09/11/2000
PC Based ISM Terminal Installation & Maintenance Manual
$13.2
NR 684021-BTA-00-101 ISSUE 3
Published Date: 12/01/2008
Form A & B: Traditional Front Wall Platform
$35.4
NR 684021-BTA-00-102 ISSUE 1
Published Date: 12/17/2008
Form A & B: Crosswall & Precast Planks
$35.4
NR 84-YS-1003/30 ISSUE H
Published Date: 04/02/2005
CCTV Monitored L.C. - Standard S.B. Control Unit Construction Details Index
$5.7