Description:

Use of Ozone and Filter Adsorbers to Remove DBP Precursors - City of Phoenix Study

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The City of Phoenix (City) currently operates four conventional water treatment plants (WTP). The City is updating its Water Quality Master Plan (WQMP). The initial phase of the WQMP update study recommended modifying the current treatment processes to achieve enhanced coagulation (EC) and incorporating additional treatment processes such as granular activated carbon (GAC) filter adsorbers and ozone at all the City WTPs. In order to develop the design and operating criteria for GAC filter adsorbers and intermediate ozonation (ozonation before filtration), the City funded a pilot study that was performed over a period of seven months from December 2002 to June 2003. This paper summarizes the key findings of this pilot study. The key objectives of the pilot testing were: can GAC filter adsorbers assist in complying with the Stage-2 D/DBP Rule requirements; what is the acceptable filter media depth for the GAC filter adsorbers; what are the benefits of backwashing with unchlorinated water; and, what are the benefits of applying ozone prior to the GAC filter adsorbers? To address the above objectives, a pilot facility was constructed and operated adjacent to the Salt River Project's Arizona Canal. This pilot facility had 11 filters; each filter was 3-inches (in) in diameter and 15 feet (ft) tall. Six of the 11 filters received plant settled water (SW) and the rest of the five filters received ozonated settled water (OSW). The pilot filters were filled with different media that included anthracite (A)/sand (S), bituminous GAC (GAC-B) and lignite GAC (GAC-L). The GACs that were used in the pilot study were of 8x20 mesh size (US Sieve) with an effective size of 1.0-1.2 millimeters (mm) and uniformity coefficient of less than 1.5. Virgin reagglomerated GAC media obtained from a leading national manufacturer was used in this study. The SW and OSW served as the feed waters to the pilot filters. Ozone was applied at a mass ratio of 0.5 mg of ozone per mg of TOC in the settled water. The average TOC of the SW ranged from 1-3 mg/L and therefore the ozone dose ranged from 0.5-1.5 mg/L. At the ozone dose of 0.5-1.5 mg/L, no significant TOC removal was observed. Ozonation lowered the average specific ultraviolet absorbance (SUVA) from 1.9 in SW to 1.4 in OSW. The bromide concentration in SW was between 80 and 110 Au/L. The low ozone dose and the moderate ozonation pHs resulted in bromate formation at less than the method detection limit (MDL) of 5 micrograms/liter (Au/L). The pilot influents and filtered waters were routinely monitored for field parameters such as pH, turbidity, temperature, ultraviolet (UV) absorbance at 254 nanometers (nm) wavelength, ozone residual in OSW and chlorine residual in backwash water. Additionally, samples were collected and sent to certified laboratories for analysis of TOC, heterotrophic plate counts (HPCs), bromide, bromate, THMs, HAAs and taste and odor (T&O) compounds. The simulated distribution system (SDS) THMs and HAAs were measured by chlorinating the samples to targeted distribution system chlorine residual levels of 0.5-1.5 mg/L at the end of 2-days and 5- days. The 2-days and 5-days correspond to the average and maximum water ages in the City's distribution system. The results and discussion are presented in four sections that correspond to the four objectives. Includes tables, figures.
Edition : Vol. - No.
File Size : 1 file , 640 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 16
Published : 11/02/2003

History


Related products

AWWA WQTC58796
Published Date: 11/02/2003
Reduction in Ozone Demand and Bromate Formation Using a Magnetic Ion Exchange Resin
$7.2
AWWA WQTC58814
Published Date: 11/02/2003
Medium Pressure UV Reactor Models for Validation Purposes
$7.2
AWWA WQTC58840
Published Date: 11/02/2003
Calibration of Pilot and Full-Scale Facilities: Ballasted Flocculation
$7.2
AWWA WQTC58849
Published Date: 11/02/2003
Short Term Impacts of Unidirectional Flushing on Water Quality
$7.2

Best-Selling Products

ISO/PAS 11585:2023
Published Date: 09/01/2023
Road vehicles - Partial driving automation - Technical characteristics of conditional hands-free driving systems
$37.2
ISO/PAS 11819-4:2013
Published Date: 03/15/2013
Acoustics - Method for measuring the influence of road surfaces on traffic noise - Part 4: SPB method using backing board
$20.4
ISO/PAS 11856:2003
Published Date: 01/01/2003
Textile floor coverings - Test methods for the determination of fibre bind
$34.2
ISO/PAS 12006-3:2001
Published Date: 10/01/2001
Building construction - Organization of information about construction works - Part 3: Framework for object-oriented information exchange
$27.6
ISO/PAS 12158:2002
Published Date: 07/01/2002
Road vehicles - Braking systems - Temperature measuring methods
$20.4
ISO/PAS 12835:2013
Published Date: 12/15/2013
Qualification of casing connections for thermal wells
$75