Full-Scale Evaluation of Chlorine Dioxide Preoxidation in Conjunction with GAC Filters for Chlorite Control

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The Stafford Springs Water Treatment Plant (SSWTP) is a 1.0-MGD facility owned and operated by the Connecticut Water Company (CWC). The plant utilizes Pulsator clarification and filtration through four feet of mono-media granular activated carbon (GAC). The GAC filter media is changed out every three years for taste and odor control. A previous study done by Metcalf & Eddy (M&E) noted that prechlorination was forming significant levels of disinfection byproducts (DBPs) within the plant and recommended the use of chlorine dioxide in lieu of chlorine for preoxidation, predisinfection, and DBP control. Subsequently, M&E and CWC conducted a two-season, full-scale trial at the SSWTP in which chlorine dioxide was utilized as a substitute for prechlorination. During the full scale trial, the effectiveness of chlorine dioxide for preoxidation was evaluated at doses from 0.8 to 3.0 mg/L, and the distance that a free residual could be sustained through the plant was determined. Distribution system DBP levels and chlorite levels were also examined. It was possible to carry a chlorine dioxide residual through the clarifier, thereby providing a significant disinfection barrier; however, a relatively high dose of chlorine dioxide was needed. Disinfection byproduct levels in the distribution system declined significantly as a result of the substitution of chlorine dioxide for pre-chlorine. This study was unique in that the chlorite removal ability of both newer and spent GAC filter media was evaluated side by side in a full-scale application. In order to examine the influence of GAC age and natural organic matter (NOM) saturation on chlorite removal, the media in two of their three GAC filters was replaced before the start of the full-scale trial. The 3-year old media in the third filter was not replaced, thereby providing an opportunity to evaluate chlorite removal through new GAC filter media with filter media close to NOM saturation. The filter containing the newer GAC media removed the majority of chlorite, while the filter containing 3 year old spent media exhibited a limited capacity for chlorite removal which continued to decline throughout the study. The study concluded that chlorine dioxide could be a viable alternative to prechlorination; however, it was not considered favorable to carry a chlorine dioxide residual through the plant due to the high doses required. The GAC filters were expected to control chlorite levels and compliance with the 1.0 mg/L chlorite maximum contaminant level (MCL) in finished water; however, modification of the GAC filter media replacement schedule was recommended. Includes 7 references, tables, figures.
Edition : Vol. - No.
File Size : 1 file
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 20
Published : 11/15/2004

History


Related products

AWWA WQTC60622
Published Date: 11/15/2004
Hydraulic Considerations for Validation and Installation of UV Reactors
$7.2
AWWA WQTC60642
Published Date: 11/15/2004
Ethics and Electronic Reporting
$7.2
AWWA WQTC60647
Published Date: 11/15/2004
Nitrate as a Fluence Monitoring Tool, Effect of Water Quality Parameters
$7.2
AWWA WQTC60727
Published Date: 11/15/2004
TMDLs - A Water Supplier Perspective
$7.2

Best-Selling Products

EIA/IS 30A
Published Date: 09/01/1987
Resistors, Rectangular Surface Mount Thick Film
EIA/IS 43AA
Published Date: 09/01/1988
Cable LAN Twisted Pair Data Communication - Detail Specification for Type 1, Outdoor Cable
EIA/IS 43AC
Published Date: 09/01/1988
Cable LAN Twisted Pair Data Communications - Detail Specification for Type 1, Riser Cable
EIA/IS 43AD
Published Date: 09/01/1988
Cable LAN Twisted Pair Data Communications - Detail Specification for Type 1, Plenum Cable
EIA/IS 43AE
Published Date: 09/01/1988
Cable LAN Twisted Pair Data Communications - Detail Specification for Type 2, Non-Plenum Cable
EIA/IS 43AF
Published Date: 09/01/1988
Cable LAN Twisted Pair Data Communications - Detail Specification for Type 2, Plenum Cable