AWWA WQTC60712 PDF

AWWA WQTC60712 PDF

Name:
AWWA WQTC60712 PDF

Published Date:
11/15/2004

Status:
Active

Description:

Microbiological Quality of Reuse Water

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
Explosive population growth and diminishing freshwater resources around the globe have now made reclaimed water use an established practice in many parts of the world. Varieties of microbial pathogens are present in wastewater and can be detected in reclaimed water. The objective of this study was to evaluate changes in quality of reclaimed water as it passes through the reclaimed water distribution systems, from treatment plant to point of use, with particular reference to pathogen occurrence. The experimental approach includes evaluating treated reclaimed water samples monthly for five months from three different treatment facilities. However, currently only one system is participating in the sampling campaign and the other two systems are scheduled to participate in October 2004. The treatment facilities are located in three different states and reuse water for toilet flushing and cooling towers in a large apartment complex, shopping mall and a national stadium. The treatments include biological treatment, membrane filtration, ultraviolet light, ozone and chlorine disinfection. The samples were analyzed for the presence of total and fecal coliforms, E. coli, E.coli O157, Pseudomonas, Aeromonas, Legionella, HPC, somatic and male-specific coliphage, enteric virus (enterovirus, hepatitis A, norwalk virus, and rotavirus) nucleic acid by RT-PCR, Giardia cysts, infectious Cryptosporidium oocysts, and physiochemical water quality parameters. Water samples were positive for low levels of total and fecal coliforms, E. coli, and Pseudomonas, suggesting that regrowth may be occurring in the distribution system. Also one sample was positive for E. coli O157 indicating that additional disinfection may be necessary to ensure the safety of reuse water. Includes 10 references, tables.
Edition : Vol. - No.
File Size : 1 file
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 5
Published : 11/15/2004

History


Related products

AWWA WQTC60638
Published Date: 11/15/2004
Salinity Issues in the Coachella Valley
$7.2
AWWA WQTC60700
Published Date: 11/15/2004
Evaluation of Several Field Test Kits for Determining Concentrations of Arsenic in Drinking Water
$7.2
AWWA WQTC60703
Published Date: 11/15/2004
Growing Old Gracefully: Assessing In-Place Filter Media at Aging Water Treatment Plants
$7.2
AWWA WQTC60718
Published Date: 11/15/2004
Prototype Testing Facility for Two-Stage Nanofiltration Membrane Seawater Desalination Process
$7.2

Best-Selling Products

CAN/ULC 554-05 (R2010)
Published Date: 10/04/2011
Standard for Water Based Agent Fire Extinguishers, Including Amendment 1
CAN/ULC 60832-09
Published Date: 04/09/2009
Insulating poles (Insulating Sticks) and Universal Tool Attachments (Fitting) for Live Working
CAN/ULC 60895-09 Draft
Published Date: 01/01/2009
Live Working - Conductive Clothing For Use at Nominal Voltage Up to 800 kV A.C. and ?600 kV D.C.
CAN/ULC 60903-09
Published Date:
Live Working - Gloves of Insulating Material
CAN/ULC 61243-3-10
Published Date: 12/01/2010
Live working -- Voltage Detectors -- Part 3: Two-Pole Low-Voltage Type
CAN/ULC 61477-05
Published Date: 01/01/2006
Live Working - Minimum Requirements for the Utilization of Tools, Devices and Equipment (CEI/IEC 61477:2001+A1:2002, IDT)