Description:

Powdered Activated Carbon and Natural Organic Matter Removal: What Is the Best Dosing Procedure?

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
Powdered activated carbon (PAC) is a well proven technology for removal of organic compounds from drinking water including natural organic matter (NOM), taste and odor compounds and pesticides (Karanfil et al., 1999; Treguer et al., 2006). PAC is normally added during the rapid mix stage along with the coagulant during coagulation so that the PAC can be incorporated into the floc and be removed along with the sludge. However, while this dosing regime enables the PAC to be removed with the floc aggregates, there is a significant reduction in the surface area available for adsorption when the PAC is contained in the floc and there is direct competition between the PAC and coagulant for the NOM being removed. Alteration of the dosing procedure has the potential of providing a significant improvement in the overall NOM removed and the clarified turbidity. This paper focuses on a real operational problem at a United Kingdom water treatment works (WTWs) and attempts to address the following key questions for PAC dosing: how and where should PAC be dosed for optimum NOM removal; what NOM does PAC remove over and above coagulation and is this dependent on dosing position; and, how is PAC removed during subsequent treatment? Two waters were collected and tested during these experiments. Raw water from Ewden water treatment works (WTWs) was taken (Sheffield, United Kingdom). This water is typical of a United Kingdom brown colored moorland water being of high dissolved organic carbon content and low alkalinity and low turbidity. Water from the same WTWs was also collected after coagulation and dissolved air flotation (DAF). Three PAC were tested: two types of Chemviron Pulsorb (Pulsorb C and Pulsorb 207 CP90, and Norit SA Super). The adsorption capacity of the three PAC carbons was tested by assessing NOM removal at a range of PAC doses and at six different pH. Raw and coagulated was added to a conical flask (250 mL). PAC was dosed at various concentrations and 80 mg/L at various pH levels. Adsorption was left for 6 hours, the time taken for adsorption to reach equilibrium. Each condition was carried out in triplicate. The two water types were tested on to determine the optimum removal of NOM using PAC and coagulation using a jar tester (Phipps and Bird). The coagulant used was ferric sulphate (Ferripol XL) and was dosed at a pre-determined optimum for this water at 10 mg/L at pH 4.0. PAC was dosed at 20 mg/L. A range of coagulant PAC dosing protocols were tested. Includes 5 references, tables, figures.
Edition : Vol. - No.
File Size : 1 file , 1.1 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 10
Published : 11/01/2008

History


Related products

AWWA WQTC69244
Published Date: 11/01/2008
Alkalinity Addition Utilizing Carbon Dioxide and Lime: An Inexpensive Solution to a Historically Expensive Problem
$7.2
AWWA WQTC69487
Published Date: 11/01/2008
Algal Characterization and Control Strategies in Water Treatment Plants
$7.2
AWWA WQTC69432
Published Date: 11/01/2008
Identification of Heterotrophic Bacteria that Colonize Pilot- and Full-Scale Chloraminated Distribution Systems
$7.2
AWWA WQTC69365
Published Date: 11/01/2008
Estimating Risk of Infection from Low-Level Intrusion Events
$7.2

Best-Selling Products

ABMA 10-1989
Published Date: 06/05/1989
Metal Balls
ABMA 11:1990 (R2008)
Published Date: 06/17/1990
Load Ratings and Fatigue Life for Roller Bearings
ABMA 11:2014 (R2020)
Published Date: 2014
Load Ratings and Fatigue Life for Roller Bearings
$16.5
ABMA 12.1:1992 (S2020)
Published Date: 04/06/1992
Instrument Ball Bearings - Metric Design
$16.5
ABMA 12.2:1992 (S2020)
Published Date: 04/06/1992
Instrument Ball Bearings - Inch Design
$16.5
ABMA 13:1987 (S2010)
Published Date: 09/02/1987
Rolling Bearing Vibration and Noise (Methods of Measuring)