BS EN 60079-0:2009 specifies the general requirements for construction, testing and
marking of electrical equipment and Ex components intended for use in explosive
atmospheres.
Unless modified by one of the standards supplementing this standard, electrical equipment
complying with this standard is intended for use in hazardous areas in which explosive
atmospheres exist under normal atmospheric conditions of
- temperature -20 C to +60 C;
- pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and
- air with normal oxygen content, typically 21 % v/v.
The application of electrical equipment in atmospheric conditions outside this range requires
special consideration and may require additional assessment and testing.
NOTE 1 Although the normal atmospheric conditions above give a temperature range for the atmosphere of -20 C
to +60 C, the normal ambient temperature range for the equipment is -20 C to +40 C, unless otherwise specified
and marked. See 5.1.1.
NOTE 2 In designing equipment for operation in explosive atmospheres under conditions other than the
atmospheric conditions given above, this standard may be used for guidance. However, additional testing related
specifically to the intended conditions of use is recommended. This is particularly important when the types of
protection 'flameproof enclosure "d"' (IEC 60079-1) and 'intrinsic safety "i"' (IEC 60079-11 or IEC 61241-11) are
applied.
NOTE 3 Requirements given in BS EN 60079-0:2009 result from an ignition hazard assessment made on electrical
equipment. The ignition sources taken into account are those found associated with this type of equipment, such as
hot surfaces, mechanically generated sparks, thermite reactions, electrical arcing and static electric discharge in
normal industrial environments.
NOTE 4 It is acknowledged that, with developments in technology, it may be possible to achieve the objectives of
the IEC 60079 series of standards in respect of explosion prevention by methods that are not yet fully defined.
Where a manufacturer wishes to take advantage of such developments, this International Standard, as well as
other standards in the IEC 60079 series, may be applied in part. It is intended that the manufacturer prepare
documentation that clearly defines how the IEC 60079 series of standards has been applied, together with a full
explanation of the additional techniques employed. The designation "Ex s" has been reserved to indicate a type of
protection that is not defined by the IEC 60079 series of standards, but may be referenced in national
requirements.
NOTE 5 Where an explosive gas atmosphere and a combustible dust atmosphere are, or may be, present at the
same time, the simultaneous presence of both should be considered and may require additional protective
measures.
BS EN 60079-0:2009 does not specify requirements for safety, other than those directly related to the
explosion risk. Ignition sources like adiabatic compression, shock waves, exothermic chemical
reaction, self ignition of dust, naked flames and hot gases/liquids, are not addressed by this
standard.
NOTE 6 Such equipment should be subjected to a hazard analysis that identifies and lists all of the potential
sources of ignition by the electrical equipment and the measures to be applied to prevent them becoming effective.
BS EN 60079-0:2009 is supplemented or modified by the following standards concerning specific
types of protection:
- IEC 60079-1: Gas - Flameproof enclosures "d";
- IEC 60079-2: Gas - Pressurized enclosures "p";
- IEC 60079-5: Gas - Powder filling "q";
- IEC 60079-6: Gas - Oil immersion "o";
- IEC 60079-7: Gas - Increased safety "e";
- IEC 60079-11: Gas - Intrinsic safety "i";
- IEC 60079-15: Gas - Type of protection "n";
- IEC 60079-18: Gas and Dust - Encapsulation "m";
- IEC 61241-1: Dust - Protection by enclosures "tD';
- IEC 61241-2 (IEC 61241-4): Dust - Pressurization "pD";
- IEC 61241-11: Dust - Intrinsic safety "iD".
NOTE 7 The former requirements of IEC 61241-18, Encapsulation "mD", have been incorporated in IEC 60079-
18.
BS EN 60079-0:2009 is supplemented or modified by the following equipment standards:
IEC 60079-25: Electrical apparatus for explosive gas atmospheres - Part 25: Intrinsically safe
systems
IEC 60079-26: Explosive atmospheres - Part 26: Equipment with equipment protection level
(EPL) Ga
IEC 60079-28: Explosive atmospheres - Part 28: Protection of equipment and transmission
systems using optical radiation
IEC 62013-1: Caplights for use in mines susceptible to firedamp - Part 1: General
requirements - Construction and testing in relation to the risk of explosion
IEC 60079-30-1: Explosive atmospheres - Part 30-1: Electrical resistance trace heating -
General and testing requirements.
BS EN 60079-0:2009 with the additional standards mentioned above, are not applicable to the
construction of
- electromedical apparatus,
- shot-firing exploders,
- test devices for exploders, and
- shot-firing circuits.
Cross References:IEC 60034-1
IEC 60034-5
IEC 60050-426
IEC 60079-1
IEC 60079-2
IEC 60079-4
IEC 60079-5
IEC 60079-6
IEC 60079-7
IEC 60079-11
IEC 60079-15
IEC 60079-18
IEC 60079-25
IEC 60079-26
IEC 60079-28
IEC 60079-30-1
IEC 60079-31
IEC 60086-1
IEC 60095-1
IEC 60192
IEC 60216-1
IEC 60216-2
IEC 60243-1
IEC 60423
IEC 60529
IEC 60622
IEC 60623
IEC 60662
IEC 60664-1
IEC 60947-1
IEC 61056-1
IEC 61241-1
IEC 61241-4
IEC 61241-11
IEC 61951-1
IEC 61951-2
IEC 62013-1
ISO 48
ISO 178
ISO 179
ISO 262
ISO 273
ISO 286-2
ISO 527-2
ISO 965-1
ISO 965-3
ISO 1817
ISO 4014
ISO 4017
ISO 4026
ISO 4027
ISO 4028
ISO 4029
ISO 4032
ISO 4762
ISO 4892-1
ANSI/UL 746B
EN 60034-1:2004
EN 60034-5:2001
EN 60079-1:2007
EN 60079-2:2007
EN 60079-5:2007
EN 60079-6:2007
EN 60079-7:2007
EN 60079-11:2007
EN 60079-15:2005
EN 60079-18:2004
EN 60079-18:2004/Corrigendum:2006
EN 60079-25:2004
EN 60079-25:2004/Corrigendum:2006
EN 60079-26:2007
EN 60079-28:2007
EN 60079-30-1:2007
EN 60079-31
EN 60086-1:2007
EN 60192:2001
EN 60216-1:2001
EN 60216-2:2005
EN 60243-1:1998
EN 60423:2007
EN 60529:1993
EN 60529:1993/Corrigendum:1993
EN 60622:2003
EN 60623:2001
EN 60662:1993
EN 60664-1:2007
EN 60947-1 2007
EN 61056-1:2003
EN 61241-1:2004/Corrigendum:2006
EN 61241-4:2006
EN 61241-11:2006
EN 61951-1:2003
EN 61951-2:2003
EN 62013-1:2006
EN ISO 178:2003
EN ISO 179
EN 20273:1991
EN ISO 527-2:1996
EN ISO 4014:2000
EN ISO 4017:2000
EN ISO 4026:2003
EN ISO 4027:2003
EN ISO 4028:2003
EN ISO 4029:2003
EN ISO 4032:2000
EN ISO 4762:2004
EN ISO 4892-1:2000
IEC/TS 60034-17
IEC/TR 60034-25
IEC 60079-10
IEC/TR 60079-12
IEC 60079-14
IEC 60079-17
IEC 60079-19
IEC/TR 60079-20
IEC 60079-27
IEC 61241-2-1:1994
IEC/TR 61241-2-2
IEC 61241-14
ISO/IEC 17000
ISO 4225: 1994
CLC/TR 50427
CLC/TS 60034-17:2004
CLC/TS 60034-25:2005
EN 60079-10:2003
EN 60079-14:2003
EN 60079-17:2007
EN 60079-19:2007
EN 60079-27:2006
EN 61241-2-2:1995
EN 61241-14:2004
EN ISO/IEC 17000:2004
94/9/EC
All current amendments available at time of purchase are included with the purchase of this document. | File Size : | 1
file
, 1.5 MB |
| ISBN(s) : | 9780580554438 |
| Note : | This product is unavailable in Ukraine, Russia, Belarus |
| Number of Pages : | 106 |
| Product Code(s) : | 30134571, 30134571, 30134571 |
| Published : | 11/30/2009 |