BS EN 61010-031:2015+A1:2021 PDF

BS EN 61010-031:2015+A1:2021 PDF

Name:
BS EN 61010-031:2015+A1:2021 PDF

Published Date:
05/20/2022

Status:
Active

Description:

Safety requirements for electrical equipment for measurement, control and laboratory use-Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement

Publisher:
British-Adopted European Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
bs-en-61010-031-2015-a1-2021_2256695

Choose Document Language:
119.63
Need Help?
This part of IEC 61010 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment.

Type A: low-voltage and high-voltage, non-attenuating probe assemblies. Non-attenuating probe assemblies that are rated for direct connection to voltages exceeding 30 V r.m.s., 42,4 V peak, or 60 V d.c., but not exceeding 63 kV. They do not incorporate components which are intended to provide a voltage divider function or a signal conditioning function, but they may contain non-attenuating components such as fuses (see Figure 1.)

Type B: high-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies that are rated for direct connection to secondary voltages exceeding 1 kV r.m.s. or 1,5 kV d.c. but not exceeding 63 kV r.m.s. or d.c. The divider function may be carried out wholly within the probe assembly, or partly within the test or measurement equipment to be used with the probe assembly (see Figure 2).

Type C: low-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies for direct connection to voltages not exceeding 1 kV r.m.s. or 1,5 kV d.c. The signal conditioning function may be carried out wholly within the probe assembly, or partly within the test or measurement equipment intended to be used with the probe assembly (see Figure 3).

Type D: low-voltage attenuating, non-attenuating or other signal conditioning probe assemblies, that are rated for direct connection only to voltages not exceeding 30 V r.m.s., or 42,4 V peak, or 60 V d.c., and are suitable for currents exceeding 8 A (see Figure 4).


All current amendments available at time of purchase are included with the purchase of this document.


File Size : 1 file , 4.1 MB
ISBN(s) : 9780580983337
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 98
Product Code(s) : 30359732, 30359732, 30359732
Published : 05/20/2022

History

BS EN 61010-031:2015+A1:2021
Published Date: 05/20/2022
Safety requirements for electrical equipment for measurement, control and laboratory use-Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
119.63 €
BS EN 61010-031:2002+A1:2008
Published Date: 03/31/2010
Safety requirements for electrical equipment for measurement, control and laboratory use-Safety requirements for hand-held probe assemblies for electrical measurement and test
110.49 €
BS EN 61010-2-031:1995
Published Date: 01/15/1995
Safety requirements for electrical equipment for measurement, control and laboratory use-Particular requirements for hand-held probe assemblies for electrical measurement and test
57.15 €

Related products

BS EN IEC 61010-2-033:2021+A11:2021
Published Date: 03/23/2022
Safety requirements for electrical equipment for measurement, control, and laboratory use-Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
110.49 €

Best-Selling Products

USACE CEGS-07416
Published Date:
Structural Standing Seam Metal Roof (SSSMR) Systems
6.60 €