This part of IEC 62282 provides test methods for the electrical, thermal and environmental
performance of small stationary fuel cell power systems that meet the following criteria:
• output: rated electric power output of less than 10 kW;
• output mode: grid-connected/independent operation or stand-alone operation with single-phase AC output or 3-phase AC output not exceeding 1 000 V, or DC output not exceeding
1 500 V;
NOTE The limit of 1 000 V for alternating current comes from the definition for "low voltage" given in IEC 60050-601:1985, 601-01-26.
• operating pressure: maximum allowable working pressure of less than 0,1 MPa (gauge) for
the fuel and oxidant passages;
• fuel: gaseous fuel (natural gas, liquefied petroleum gas, propane, butane, hydrogen, etc.)
or liquid fuel (kerosene, methanol, etc.);
• oxidant: air.
This document describes type tests and their test methods only. No routine tests are required
or identified, and no performance targets are set in this document.
| File Size : | 1
file
, 2.5 MB |
| ISBN(s) : | 9780539054484 |
| Note : | This product is unavailable in Ukraine, Russia, Belarus |
| Number of Pages : | 90 |
| Product Code(s) : | 30397960, 30397960, 30397960 |
| Published : | 07/08/2022 |