Description:

Backflow Preventers and Vacuum Breakers

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$25.2
Need Help?
This is a searchable PDF.

B64.0-01 1.

Scope 1.1 Vacuum breakers and backflow preventers that are specified in the B64 Series of CSA Standards include only those devices that are designed for use in potable water supply systems to prevent cross

1.2 This Standard provides definitions, general requirements, test methods, marking, and instructions that are common to some or all of the B64 Series of CSA Standards.

1.3 This Standard is not a complete Standard in itself and is intended to be used in conjunction with one of the other Standards in the B64 Series of CSA Standards to form a complete Standard for a particular type of vacuum breaker or backflow preventer.

1.4 In this Standard, #shall# is used to express a requirement, i.e., a pro vision that the user is obliged to satisfy in order to comply with the standard; #should# is used to express a recommendation or that which is advised but not required; and #may# is used to express an option or that which is permissible within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Legends to equations and figures are considered requirements.

1.5 This Standard is written in SI (metric) units; for conversion tables, see Appendix A.

Vacuum is expressed in pressure below ambient.

All pipe sizes are shown as nominal pipe sizes (NPS).

B64.1.1-01 1.

Scope This Standard applies to vacuum breakers of the atmospheric type (AVB).

B64.1.2-01 1.

Scope This Standard applies to vacuum breaker assemblies of the pressure type (PVB).

B64.2-01 1.

Scope This Standard applies to vacuum breakers of the hose connection type (HCVB). CSA Standards B64.2.1 and B64.2.1.1 provide re quirements for HCVB devices incorporating a manual draining feature.

CSA Standard B64.2.2 provides requirements for HCVB devices incorporating an automatic draining feature.

B64.2.1-01 1.

Scope This Standard applies to vacuum breakers of the hose connection type (HCVB) that incorporate a draining feature requiring manual operation.

B64.1.1-01 1.

Scope This Standard applies to vacuum breakers of the hose connection type that have two checks (HCDVB) and that incorporate a draining feature that requires a manual operation. The second (downstream) check is field-testable.

B64.2.2-01 1.

Scope This Standard applies to vacuum breakers of the hose connection type (HCVB) that incorporate an automatic draining feature that does not require manual operation.

B64.3-01 1.

Scope This Standard applies to backflow preventers of the dual check valve type with atmospheric port (DCAP).

B64.3.1-01 1.

Scope This Standard applies to backflow preventers of the dual check valve type with atmospheric port for carbonators (DCAPC).

B64.4-01 1.

Scope This Standard applies to backflow preventer assemblies of the reduced pressure principle type (RP).

B64.4.1-01 1.

Scope This Standard applies to backflow preventer assemblies of the reduced pressure principle type that are specifically designed for use in fire protection systems (RPF).

B64.5-01 1.

Scope This Standard applies to backflow preventer assemblies of the double check valve type (DCVA).

B64.5.1-01 1.

Scope This Standard applies to backflow preventer assemblies of the double check valve type that are specifically designed for use in fire protection systems (DCVAF).

B64.6-01 1.

Scope This Standard applies to backflow preventers of the dual check valve type (DuC).

B64.6.1-01 1.

Scope This Standard applies to backflow preventers of the dual check valve type that are specifically designed for use in fire protection systems (DuCF).

B64.7-01 1.

Scope

1.1 This Standard applies to vacuum breakers for use on laboratory faucets (LFVB).

1.2 Laboratory faucet vacuum breakers are installed on the discharge side of the last control valve and are not intended for use u nder constant pressure conditions.

B64.8.-01 1.

Scope This Standard applies to backflow preventers of the dual check valve type with an intermediate vent (DuCV).

These devices are designed to be used on individual outlets or appliances with flow rates of 0.25 L/s or less.

B64.9-01 1.

Scope This Standard applies to backflow preventer assemblies of the single check valve type that are specifically designed for use in fire protection systems (SCVAF).
File Size : 1 file , 580 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 92
Published : 01/01/2001

History

CAN/CSA B64 SERIES-07
Published Date: 07/01/2007
Backflow Preventers and Vacuum Breakers (Consists of B64.0, B64.1.1, B64.1.2, B64.1.3, B64.2, B64.2.1, B64.2.1.1, B64.2.2, B64.3, B64.3.1, B64.4, B64.4.1, B64.5, B64.5.1, B64.6, B64.6.1, B64.7, B64.8 and B64.9), Includes Update No. 1 (2008)
$87.3
CAN/CSA B64 SERIES-01
Published Date: 01/01/2001
Backflow Preventers and Vacuum Breakers
$25.2

Related products

CAN/CSA E742-94 (R2009)
Published Date: 12/18/1999
Isolating Transformers and Safety Isolating Transformers - Requirements (Adopted IEC 742:1983, first edition, including Amendment 1:1992, with Canadian deviations)
$96
CAN/CSA G312.3-M92 (R1998)
Published Date: 04/28/2000
Metric Dimensions for Structural Steel Shapes and Hollow Structural Sections
$12.6
CAN/CSA M789.11-97 (R2006)
Published Date: 02/16/2000
Agricultural Tractors - Test Procedures - Part 11: Steering Capability of Wheeled Tractors (Adopted ISO 789-11:1996)
$17.4
CAN/CSA C802.2-18 (R2023)
Published Date: 10/01/2018
Test method and minimum efficiency values for dry-type transformers
$47.4

Best-Selling Products

SN-ISO/TS 10993-19:2006
Published Date: 07/01/2014
Biological evaluation of medical devices — Part 19: Physico-chemical, morphological and topographical characterization of materials
SN-ISO/TS 10993-19:2020
Published Date: 12/14/2020
Biological evaluation of medical devices — Part 19: Physico-chemical, morphological and topographical characterization of materials
SN-ISO/TS 10993-20:2006
Published Date: 07/01/2014
Biological evaluation of medical devices — Part 20: Principles and methods for immunotoxicology testing of medical devices
SN-ISO/TS 14067:2013
Published Date: 07/01/2013
Greenhouse gases — Carbon footprint of products — Requirements and guidelines for quantification and communication
SN-ISO/TS 14092:2020
Published Date: 09/02/2021
Adaptation to climate change - Requirements and guidance on adaptation planning for local governments and communities
SN-ISO/TS 14812:2022
Published Date: 09/20/2023
Intelligent transport systems - Vocabulary