CAN/CSA C22.2 No. 60079-11:11 PDF

CAN/CSA C22.2 No. 60079-11:11 PDF

Name:
CAN/CSA C22.2 No. 60079-11:11 PDF

Published Date:
03/29/2012

Status:
Active

Description:

Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" (Adopted IEC 60079-11:2006, fifth edition, 2006-07, with Canadian deviations)

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
can-csa-c22-2-no-60079-11-11_1830252

Choose Document Language:
94.50 €
Need Help?
Scope

This part of IEC 60079 specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive gas atmosphere and for associated apparatus, which is intended for connection to intrinsically safe circuits which enter such atmospheres.

This type of protection is applicable to electrical apparatus in which the electrical circuits themselves are incapable of causing an explosion in the surrounding explosive atmospheres.

This standard is also applicable to electrical apparatus or parts of electrical apparatus located outside the explosive gas atmosphere or protected by another type of protection listed in IEC 60079-0, where the intrinsic safety of the electrical circuits in the explosive gas atmosphere may depend upon the design and construction of such electrical apparatus or parts of such electrical apparatus. The electrical circuits exposed to the explosive gas atmosphere are evaluated for use in such an atmosphere by applying this standard.

The requirements for intrinsically safe systems are provided in IEC 60079-25. The requirements for intrinsically safe concepts for fieldbus are provided in IEC 60079-27.

This standard supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirements of this standard shall take precedence.

If associated apparatus is placed in the explosive gas atmosphere, it must be protected by an appropriate type of protection listed in IEC 60079-0, and then the requirements of that method of protection together with the relevant parts of IEC 60079-0 also apply to the associated apparatus.
Edition : 1st
File Size : 1 file , 2.2 MB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 268
Product Code(s) : 2421481, 2421481
Published : 03/29/2012

History

CAN/CSA C22.2 No. 60079-11:14 (R2023)
Published Date: 02/01/2014
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" (Adopted IEC 60079-11:2011, Modified)
99.00 €
CAN/CSA C22.2 No. 60079-11:11
Published Date: 03/29/2012
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" (Adopted IEC 60079-11:2006, fifth edition, 2006-07, with Canadian deviations)
94.50 €
CAN/CSA E60079-11-02 (R2011)
Published Date: 03/01/2002
Electrical Apparatus for Explosive Gas Atmospheres - Part 11: Intrinsic Safety "i" (Adopted CEI/IEC 60079-11:1999, fourth edition, 1999-02, with Canadian deviations)
91.20 €

Related products


Best-Selling Products

NSC 373-2013e
Published Date: 03/10/2014
Sustainability Assessment - Natural Dimension Stone
NSC 373 Chain of Custody Standard
Published Date: 03/24/2014
NSC (Safety) 023160000
Published Date: 01/01/2010
Injury Facts Book
24.90 €
NSC (Safety) 062060000
Published Date:
Protecting Workers' Lives: A Safety and Health Guide for Unions
45.30 €
NSC (Safety) 120270000
Published Date:
OSHA Inspections: Preparation and Response
74.40 €
NSC (Safety) 120760000
Published Date:
Beyond Workers' Comp: A Human Resources Guide to Building Safety into Your Organization
17.40 €