CAN/CSA C22.2 NO. 60601-2-20:23 PDF

CAN/CSA C22.2 NO. 60601-2-20:23 PDF

Name:
CAN/CSA C22.2 NO. 60601-2-20:23 PDF

Published Date:
03/27/2023

Status:
Active

Description:

Medical electrical equipment - Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators (Adopted IEC 60601-2-20:2020, third edition, 2020-09, with Canadian deviations)

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
can-csa-c22-2-no-60601-2-20-23_2562901

Choose Document Language:
113.40 €
Need Help?

CSA Preface 

This is the third edition of CSA C22.2 No. 60601-2-20, Medical electrical equipment — Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60601-2-20 (third edition, 2020-09). It supersedes the previous edition, published in 2010 as CSA C22.2 No. 60601-2-20 (adopted IEC 60601-2-20:2009). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as "CSA C22.2 No. 60601-2-20" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC Standard 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Application of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health and Well-being. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. 

Scope and object 

Clause 1 of the general standard1 applies, except as follows: 

201.1.1 Scope Replacement: This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT TRANSPORT INCUBATOR equipment, as defined in 201.3.208, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document, except in 7.2.13 and 8.4.1 of the general standard. 

NOTE See also 4.2 of the general standard. This particular standard specifies safety requirements for INFANT TRANSPORT INCUBATORS, but alternate methods of compliance with a specific clause, by demonstrating equivalent safety, will not be judged as non-compliant, if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device. This particular standard does not apply to: – devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information, see IEC 60601-2-35 [1]2; – INFANT INCUBATORS which are not INFANT TRANSPORT INCUBATOR; for information see IEC 60601-2-19 [2]; – INFANT RADIANT WARMERS; for information, see IEC 60601-2-21 [3]; – INFANT PHOTOTHERAPY; for information, see IEC 60601-2-50 [4]. 201.1.2 Object Replacement: The object of this particular standard is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for INFANT TRANSPORT INCUBATORS as defined in 201.3.208, which minimize HAZARDS to the PATIENT and OPERATOR, and to specify tests by which compliance with the requirements can be verified.


Edition : 3rd
File Size : 1 file , 3.2 MB
ISBN(s) : 9781488347450
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 119
Product Code(s) : 2430791, 2430791
Published : 03/27/2023

History

CAN/CSA C22.2 NO. 60601-2-20:23
Published Date: 03/27/2023
Medical electrical equipment - Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators (Adopted IEC 60601-2-20:2020, third edition, 2020-09, with Canadian deviations)
113.40 €
CAN/CSA C22.2 NO. 60601-2-20:10 + A1 (CONSOLIDATED) (R2019)
Published Date: 02/01/2019
Medical electrical equipment - Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators
133.80 €
CAN/CSA C22.2 NO. 60601-2-20-10 (R2019)
Published Date: 01/01/2010
Medical electrical equipment - Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators (Adopted IEC 60601-2-20:2009, second edition, 2009-02), Includes Corrigendum 1 (2012) and Corrigendum 2 (2019)
69.30 €

Related products

CAN/CSA C22.2 NO. 60601-2-21:23
Published Date: 03/26/2023
Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers (Adopted IEC 60601-2-21:2020, third edition, 2020-09, with Canadian deviations)
95.70 €
CAN/CSA C22.2 NO. 60601-2-41:23
Published Date: 03/28/2023
Medical electrical equipment — Part 2-41: Particular requirements for the basic safety and essential performance of surgical luminaires and luminaires for diagnosis (Adopted IEC 60601-2-41:2021, third edition, 2021-09, with Canadian devbiations)
126.30 €
CAN/CSA C22.2 No. 60601-2-49:11 (R2021)
Published Date: 03/29/2012
Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment (Adopted IEC 60601-2-49:2011, second edition, 2011-02)
75.60 €
CAN/CSA C22.2 NO. 80601-2-12:24
Published Date: 07/31/2024
Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators (Adopted ISO 80601-2-12:2023, third edition, 2023-11, with Canadian deviations)
99.00 €

Best-Selling Products

1A1W1S1 Archive Product 105
Published Date: 01/01/2000
Welding Inspection Handbook
1A1W1S1 Archive Product 111
Published Date: 02/01/1981
Welding Technology for the Aerospace Industry
1A1W1S1 Archive Product 115
Published Date: 01/01/2002
Structural Welding Code - Steel
1A1W1S1 Archive Product 138
Published Date: 01/01/2002
Standard Welding Procedure Specification (Swps) for Gas Tungsten Arc Welding of Carbon Steel to Austenitic Stainless Steel (M-1, P-1 or S-1 to M-8, P-8, or S-8), 18 through 10 Gauge, in the As-Welded Condition, with or without Backing
1A1W1S1 Archive Product 142
Published Date: 01/01/2001
Ventilation Guide for Weld Fume
1A1W1S1 Archive Product 167
Published Date: 08/01/2008
Structural Welding Code Steel Bundled Set A