CAN/CSA C22.2 NO. 60601-2-4:12 (R2021) + A1:19 (R2021) CONSOLIDATED PDF

CAN/CSA C22.2 NO. 60601-2-4:12 (R2021) + A1:19 (R2021) CONSOLIDATED PDF

Name:
CAN/CSA C22.2 NO. 60601-2-4:12 (R2021) + A1:19 (R2021) CONSOLIDATED PDF

Published Date:
10/01/2019

Status:
Active

Description:

Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators (Adopted IEC 60601-2-4:2010, third edition, 2010-12, consolidated with amendment 1:2018, with Canadian deviations)

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$202.5
Need Help?
Scope:

This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of CARDIAC DEFIBRILLATORS, hereafter referred to as ME EQUIPMENT.

If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.

HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard.

NOTE See also 4.2 of the general standard.

This particular standard does not apply to implantable DEFIBRILLATORS, remote control DEFIBRILLATORS, or separate stand-alone cardiac monitors (which are standardized by IEC 60601-2-27:2011 [2]2). Cardiac monitors which use separate ECG monitoring electrodes are not within the scope of this standard unless they are used as the sole basis for AED rhythm recognition detection or beat detection for synchronized cardioversion. DEFIBRILLATOR electrodes as described in 201.108 can also be used for ECG monitoring; however, due to the larger electrode area, the requirements of IEC 60601-2-27 are not applicable for DEFIBRILLATOR ELECTRODES.

Defibrillation waveform technology is evolving rapidly. Published studies indicate that the effectiveness of waveforms varies. The choice of a particular waveform including waveshape, delivered energy, efficacy, and safety has been specifically excluded from the scope of this standard.

However, due to the critical importance of the therapeutic waveform, comments have been added to the rationale which addresses considerations in waveform selection.

The object of this particular standard is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for cardiac defibrillators as defined in 201.3.202.
File Size : 2 files , 6.2 MB
ISBN(s) : 9781488326547
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 354
Product Code(s) : 2427705, 2427705
Published : 10/01/2019

History

CAN/CSA C22.2 NO. 60601-2-4:12 (R2021) + A1:19 (R2021) CONSOLIDATED
Published Date: 10/01/2019
Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators (Adopted IEC 60601-2-4:2010, third edition, 2010-12, consolidated with amendment 1:2018, with Canadian deviations)
$202.5
CAN/CSA C22.2 NO. 60601-2-4:12 (R2021)
Published Date: 03/29/2012
Medical Electrical Equipment - Part 2-4: Particular Requirements for the Safety of Cardiac Defibrillators
$88.5
CAN/CSA C22.2 NO. 60601-2-4-04
Published Date: 04/30/2004
Medical Electrical Equipment - Part 2-4: Particular Requirements for the Safety of Cardiac Defibrillators
$82.8

Related products

CAN/CSA C22.2 NO. 60601-2-54:24
Published Date: 07/27/2024
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy (Adopted IEC 60601-2-54:2022, second edition, 2022-09, with Canadian deviations)
$90
CAN/CSA C22.2 NO. 80601-2-12:24
Published Date: 07/31/2024
Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators (Adopted ISO 80601-2-12:2023, third edition, 2023-11, with Canadian deviations)
$99

Best-Selling Products

UNE-CEN ISO/TS 11133-1:2009
Published Date: 09/16/2009
Microbiology of food and animal feeding stuffs - Guidelines on preparation and production of culture media - Part 1: General guidelines on quality assurance for the preparation of culture media in the laboratory (ISO/TS 11133-1:2009)
UNE-CEN ISO/TS 11133-2:2006
Published Date: 05/10/2006
Microbiology of food and animal feeding stuffs - Guidelines on preparation and production of culture media - Part 2: Practical guidelines on performance testing of culture media (ISO/TS 11133-2:2003)
UNE-CEN ISO/TS 11135-2:2009 EX
Published Date: 09/02/2009
Sterilization of health care products - Ethylene oxide - Part 2: Guidance on the application of ISO 11135-1 (ISO/TS 11135-2:2008)
UNE-CEN ISO/TS 15874-7:2005
Published Date: 01/12/2005
Plastics piping systems for hot and cold water installations - Polypropylene (PP) - Part 7: Guidance for the assessment of conformity (ISO/TS 15874-7:2003)
UNE-CEN ISO/TS 15875-7:2005
Published Date: 01/12/2005
Plastics piping systems for hot and cold water installations - Crosslinked polyethylene (PE-X) - Part 7: Guidance for the assessment of conformity (ISO/TS 15875-7:2003)
UNE-CEN ISO/TS 15876-7:2005
Published Date: 01/12/2005
Plastics piping systems for hot and cold water installations - Polybutylene (PB) - Part 7: Guidance for the assessment of conformity (ISO/TS 15876-7:2003)