CAN/CSA C22.2 NO. 60601-2-50:23 PDF

CAN/CSA C22.2 NO. 60601-2-50:23 PDF

Name:
CAN/CSA C22.2 NO. 60601-2-50:23 PDF

Published Date:
03/27/2023

Status:
Active

Description:

Medical electrical equipment - Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment (Adopted IEC 60601-2-50:2020, third edition, 2020-09)

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$95.7
Need Help?

CSA Preface 

This is the third edition of CSA C22.2 No. 60601-2-50, Medical electrical equipment — Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60601-2-50 (third edition, 2020-09). It supersedes the previous edition, published in 2010 as CAN/CSA-C22.2 No. 60601-2-50 (adopted IEC 60601-2-50:2009). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as "CSA C22.2 No. 60601-2-50" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC Standard 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Application of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health and Well-being. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. 

Scope and object 

Clause 1 of the general standard1 applies, except as follows: 

201.1.1 * Scope Replacement: This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT PHOTOTHERAPY EQUIPMENT, as defined in 201.3.203, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document, except in 7.2.13 and 8.4.1 of the general standard. 

NOTE See also 4.2 of the general standard. This particular standard specifies safety requirements for INFANT PHOTOTHERAPY EQUIPMENT, but alternate methods of compliance with a specific clause by demonstrating equivalent safety will not be judged as non-compliant if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device. This document does not apply to: – devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information, see IEC 60601-2-35 [1]2; – INFANT INCUBATORS; for information, see IEC 60601-2-19 [2]; – INFANT TRANSPORT INCUBATORS; for information, see IEC 60601-2-20 [3]; – INFANT RADIANT WARMERS; for information, see IEC 60601-2-21 [4]. 201.1.2 Object Replacement: The object of this particular standard is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for INFANT PHOTOTHERAPY EQUIPMENT (as defined in 201.3.203), which reduce the safety HAZARDS to PATIENTS and OPERATORS as much as possible and to specify tests for demonstrating compliance with these requirements.


Edition : 3rd
File Size : 1 file , 3.1 MB
ISBN(s) : 9781488347504
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 88
Product Code(s) : 2430801, 2430801
Published : 03/27/2023

History

CAN/CSA C22.2 NO. 60601-2-50:23
Published Date: 03/27/2023
Medical electrical equipment - Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment (Adopted IEC 60601-2-50:2020, third edition, 2020-09)
$95.7
CAN/CSA C22.2 NO. 60601-2-50-10 (R2018)
Published Date: 01/01/2010
Medical electrical equipment - Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment (Adopted IEC 60601-2-50:2009) Includes Corrigendum 1:2011
$50.4
CAN/CSA C22.2 NO. 60601-2-50-03
Published Date: 09/01/2003
Medical Electrical Equipment - Part 2-50: Particuar Requirements for the Safety of Infant Phototherapy Equipment (Adopted IEC 60601-2-50:2000, first edition, 2000-07)
$27

Related products

CAN/CSA -C22.2 NO. 60601-1-9:15 (R2019) +A2:21 (CONSOLIDATED)
Published Date: 09/09/2022
Medical electrical equipment - Part 1-9: General requirements for basic safety and essential performance - Collateral standard: Requirements for environmentally conscious design (Adopted IEC 60601-1-9:2007, edition 1:2007 consolidated with amendment 1:2013 and amendment 2:2020, with Canadian deviations)
$84.9
CAN/CSA C22.2 NO. 60601-2-39:23
Published Date: 01/25/2023
Medical electrical equipment -- Part 2-39: Particular requirements for basic safety and essential performance of peritoneal dialysis equipment
$75.6

Best-Selling Products

ISO/IEC TS 15504-9:2011
Published Date: 08/01/2011
Information technology - Process assessment - Part 9: Target process profiles
$29.7
ISO/IEC TS 29140:2020
Published Date: 10/01/2020
Information technology for learning, education and training - Nomadicity and mobile technologies
$55.5