Preface

This is the fifth edition of CSA C862, Performance of incandescent reflector lamps. It supersedes the previous editions, published in 2001, 1997, 1995, and 2009.

Scope

1.1
This Standard describes testing procedures and states performance requirements for general service incandescent and tungsten halogen reflector lamps.

1.2
This Standard includes performance requirements for
(a) wattage;
(b) lamp efficacy;
(c) rated luminous flux;

(d) centre beam intensity; and
(e) rated life.

1.3
This Standard applies to incandescent and tungsten halogen reflector lamps designed for general lighting use that have
(a) a rated wattage from 40 W up to and including 205 W;
(b) an operating capability between 110 and 130 V;
(c) an E26/24 single contact, or E26/50-39 skirted, medium screw base; and
(d) a bulb diameter greater than 57 mm.

1.4
This Standard does not apply to any of the following:
(a) coloured lamps;
(b) lamps that
  1. are of rough (or vibration) service type and are specifically marked and marketed as rough (or vibration) service lamps;
  2. have a coating or other containment system to retain glass fragments if the lamp is shattered and are specifically marked and marketed as impact-resistant lamps; or
  3. contain a filter that suppresses yellow and green portions of the spectrum and are specifically marked and marketed for plant growth use;
(c) infrared heat lamps;
(d) lamps used in mines or in airfield, aircraft, automotive, marine, aquarium, terrarium, or vivarium applications;
(e) a bulb shape designated as BR as described in NEMA/ANSI C79.1 with
  1. a diameter of 95.25 mm (BR 30) and a rated power of less than or equal to 50 W;
  2. a diameter of 95.25 mm (BR 30) and a rated power of 65 W;
  3. a diameter of 127 mm (BR 40) and a rated power of less than or equal to 50 W; or
  4. a diameter of 127 mm (BR 40) and a rated power of 65 W;
(f) a bulb shape designated as ER as described in NEMA/ANSI C79.1 with
  1. a diameter of 95.25 mm (ER 30) and a rated power of less than or equal to 50 W;
  2. a diameter of 127 mm (ER 40) and a rated power of less than or equal to 50 W; or
  3. a diameter of 127 mm (ER 40) and a rated power of 65 W;
(g) a bulb shape designated as R as described in NEMA/ANSI C79.1 with a diameter of 63.5 mm (R 20) and a rated power of less than or equal to 45 W;
(h) bowl mirror lamps (e.g., silverbowl); or
(i) lamps for heat-sensitive applications (i.e., dichroic cool beam).

1.5
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.
   Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
   Notes to tables and figures are considered part of the table or figure and may be written as requirements.
   Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.


Edition : 5th
File Size : 1 file , 920 KB
ISBN(s) : 9781554919703
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 22
Product Code(s) : 2421930, 2422381, 2421930
Published : 09/30/2012

History

CAN/CSA C862-12 (R2022)
Published Date: 09/30/2012
Performance of Incandescent Reflector Lamps, Includes Update No. 1 (2014)
$41.1
CAN/CSA C862-01 (R2006)
Published Date: 08/01/2001
Performance of Incandescent Reflector Lamps
$18.9
CAN/CSA C862-97
Published Date: 08/01/1997
Performance of Incandescent Reflector Lamps
$9.6

Related products

CAN/CSA C382-11 (R2021)
Published Date: 02/01/2011
Energy performance of televisions and displays, Includes Update No. 1 (2011)
$41.7
CAN/CSA C360-13 (R2023)
Published Date: 09/01/2013
Energy Performance, Water Consumption and Capacity of Household Clothes Washers
$37.2
CAN/CSA C813.1-14 (R2024)
Published Date: 05/01/2014
Performance Test Method for Uninterruptible Power Supplies
$24

Best-Selling Products

AENOR EA 0007
Published Date: 09/07/2016
Requisitos del sistema de seguimiento y agregación de los precios del papel para reciclar.
$12.9
AENOR EA 0014
Published Date: 02/14/2003
Marcado por impresión de los elementos calefactores que utilizan cable calefactor según la Norma UNE 21155-1.
$5.4
AENOR EA 0032
Published Date: 07/11/2007
Equipos estabilizadores de tensión y reductores de flujo luminoso en cabecera de línea. Requisitos generales y de seguridad
$23.7
AENOR EA 0039
Published Date: 02/04/2009
Cables multiconductores de tensión asignada 0,6/1 kV no propagadores del incendio, aislados con polietileno reticulado y con cubierta de poliolefina, para utilizar como instalación fija en circuitos de control.
$18.9
AENOR EA 0042
Published Date: 12/23/2014
Aparamenta de baja tensión. Equipos auxiliares. Conjuntos de bloques de conexión para la verificación de contadores de energía.
$22.2
AENOR EA 0051
Published Date: 12/23/2014
Cables eléctricos de distribución con aislamiento extruido, de tensión asignada desde 3,6/6 (7,2) kV hasta 20,8/36 (42) kV inclusive. Cables unipolares y unipolares reunidos con aislamiento de HPTE. Cables con cubierta de compuesto de poliolefina (tipo 1, tipo 2 y tipo 3)
$22.2