CEI CLC/TR 60919-2 PDF

CEI CLC/TR 60919-2 PDF

Name:
CEI CLC/TR 60919-2 PDF

Published Date:
11/01/2013

Status:
[ Active ]

Description:

Performance of high-voltage direct current (HVDC) systems with linecommutated converters Part 2: Faults and switching

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$70.8
Need Help?

This part of IEC 60919 which is a technical report provides guidance on the transient performance and fault protection requirements of high voltage direct current (HVDC) systems. It concerns the transient performance related to faults and switching for two-terminal HVDC systems utilizing 12-pulse converter units comprised of three-phase bridge (double way) connections but it does not cover multi-terminal HVDC transmission systems. However, certain aspects of parallel converters and parallel lines, if part of a two-terminal system, are discussed. The converters are assumed to use thyristor valves as the bridge arms, with gapless metal oxide arresters for insulation co-ordination and to have power flow capability in both directions. Diode valves are not considered in this report.

Only line-commutated converters are covered in this report, which includes capacitor commutated converter circuit configurations. General requirements for semiconductor linecommutated converters are given in IEC 60146-1-1, IEC 60146-1-2 and IEC 60146-1-3. Voltage-sourced converters are not considered.

The report is comprised of three parts. IEC 60919-2, which covers transient performance, will be accompanied by companion documents, IEC 60919-1 for steady-state performance and IEC 60919-3 for dynamic performance. An effort has been made to avoid duplication in the three parts. Consequently users of this report are urged to consider all three parts when preparing a specification for purchase of a two-terminal HVDC system.

Readers are cautioned to be aware of the difference between system performance specifications and equipment design specifications for individual components of a system. While equipment specifications and testing requirements are not defined herein, attention is drawn to those which could affect performance specifications for a system. Note that detailed seismic performance requirements are excluded from this technical report. In addition, because of the many possible variations between different HVDC systems, these are not considered in detail. Consequently this report should not be used directly as a specification for a specific project, but rather to provide the basis for an appropriate specification tailored to fit actual system requirements for a particular electric power transmission scheme. This report does not intend to discriminate the responsibility of users and manufacturers for the work specified.

Terms and definitions for high-voltage direct current (HVDC) transmission used in this report are given in IEC 60633.

Since the equipment items are usually separately specified and purchased, the HVDC transmission line, earth electrode line and earth electrode are included only because of their influence on the HVDC system performance.

For the purpose of this report, an HVDC substation is assumed to consist of one or more converter units installed in a single location together with buildings, reactors, filters, reactive power supply, control, monitoring, protective, measuring and auxiliary equipment. While there is no discussion of a.c. switching substations in this report, a.c. filters and reactive power sources are included, although they may be connected to an a.c. bus separate from the HVDC substation.


Edition : 13
File Size : 1 file , 1.7 MB
Number of Pages : 68
Published : 11/01/2013

History


Related products

CEI EN 50163
Published Date: 10/01/2006
Railway applications - Supply voltages of traction systems
$29.4
CEI EN 61143-1
Published Date: 06/01/1997
Electrical measuring instruments – X-t recorders - Part 1: Definitions and requirements
$30.3
CEI EN IEC 60079-10-1
Published Date: 09/01/2021
Explosive atmospheres Part 10-1: Classification of areas - Explosive gas atmospheres
$66.6
CEI EN 62386-301
Published Date: 01/01/2018
Digital addressable lighting interface Part 301: Particular requirements - Input devices - Push buttons
$17.7

Best-Selling Products

SN-CEN/CLC/ETSI TR 101550:2014
Published Date: 02/19/2014
Documents relevant to EN 301 549 "Accessibility requirements suitable for public procurement of ICT products and services in Europe"
SN-CEN/CLC/ETSI TR 101550:2022
Published Date: 07/01/2022
Documents relevant to EN 301 549 (V1.1.1) "Accessibility requirements suitable for public procurement of ICT products and services in Europe"
SN-CEN/CLC/ETSI TR 101551:2014
Published Date: 02/19/2014
Guidelines on the use of accessibility award criteria suitable for public procurement of ICT products and services in Europe
SN-CEN/CLC/ETSI TR 50572:2011
Published Date: 12/16/2011
Functional Reference Architecture for Communications in Smart Metering Systems