CEI CLC/TS 50549-1 PDF

CEI CLC/TS 50549-1 PDF

Name:
CEI CLC/TS 50549-1 PDF

Published Date:
06/01/2015

Status:
[ Revised ]

Description:

Requirements for the connection of a generating plant to a distribution system Part 1: Connection to a LV distribution system and above 16 A

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$21.9
Need Help?

The purpose of this Technical Specification is to provide technical guidance on the requirements for generating plants which can be operated in parallel with a distribution network. For practical reasons, this Technical Specification refers to the distribution system operator in case settings have to be defined and/or provided, even when these settings are to be defined and/or provided by another actor according to national and European legal framework.

NOTE 1 This includes European network codes and their national implementation, as well as further national regulations.

NOTE 2 Further national requirements especially for the connection to the distribution network and the operation of the generating plant can apply.

The requirements of this Technical Specification apply to all generating plants, electrical machinery and electronic equipment, irrespective of the kind of primary energy source and irrespective of the presence of loads in the producer’s network that meet all of the following conditions:

– converting any primary energy source into AC electricity;

– connected to a LV distribution network and rated at more than 16 A per phase;

– intended to operate in parallel with this distribution network under normal network operating conditions.

NOTE 3 Generating plants rated up to and including 16 A per phase are covered by EN 50438.

NOTE 4 Generating plants connected to a MV distribution network fall into the scope of CLC/TS 50549-2.

Unless stated differently by the DSO generating plants connected to a medium voltage distribution network with a maximum apparent power up to 100 kVA can comply with this Technical Specification as alternative to the requirements of CLC/TS 50549-2. A different threshold may be defined by the DSO.

This Technical Specification defines connection requirements.

This Technical Specification recognizes the existence of National Standards, Network Codes, and specific technical requirements of the DSOs. These should be complied with.

Excluded from the scope are:

– the selection and evaluation of the point of connection;

– power system impact assessment;

– connection assessment;

– island operation of generating plants, both intentional and unintentional, where no part of the distribution network is involved;

– active front ends of drives feeding energy back into the distribution network for short duration;

– requirements for the safety of personnel as they are already adequately covered by existing European Standards.


Edition : 15
File Size : 1 file , 800 KB
Number of Pages : 46
Published : 06/01/2015

History

CEI EN 50549-1
Published Date: 07/01/2019
Requirements for generating plants to be connected in parallel with distribution networks Part 1: Connection to a LV distribution network - Generating plants up to and including Type B
$41.1
CEI CLC/TS 50549-1
Published Date: 06/01/2015
Requirements for the connection of a generating plant to a distribution system Part 1: Connection to a LV distribution system and above 16 A
$21.9

Related products

CEI EN 60654-1
Published Date: 04/01/1998
Industrial-process measurements and control equipment – Operating conditions - Part 1: Climatic conditions
$18.3
CEI EN 62328-1
Published Date: 05/01/2006
Multimedia home server systems - Interchangeable volume/file structure adaptation for broadcasting receivers Part 1: General description and architecture
$21.9
CEI EN 60700-1
Published Date: 03/01/2016
Thyristor valves for high voltage direct current (HVDC) power transmission Part 1: Electrical testing
$20.4
CEI EN IEC 60684-3-247
Published Date: 03/01/2020
Flexible insulating sleeving Part 3: Specifications for individual types of sleeving - Sheet 247: Heatshrinkable, polyolefin sleeving, dual wall, not flame retarded, thick and medium wall
$13.5

Best-Selling Products

HFES 100
Published Date: 01/01/2007
Human Factors Engineering of Computer Workstations
$28.5
HFES 200
Published Date: 01/01/2008
Human Factors Engineering of Software User Interfaces
$60
HFES 300
Published Date: 01/01/2004
Guidelines for Using Anthropometric Data in Product Design
$25.5
HFES HFES 400
Published Date: 01/01/2021
Human Readiness Level Scale in the System Development Process