CEI EN 50121-4 PDF

CEI EN 50121-4 PDF

Name:
CEI EN 50121-4 PDF

Published Date:
05/01/2017

Status:
[ Revised ]

Description:

Railway applications - Electromagnetic compatibility Part 4: Emission and immunity of the signalling and telecommunications apparatus

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
cei-en-50121-4_2751125

Choose Document Language:
11.70 €
Need Help?

This European Standard applies to signalling and telecommunication apparatus that is installed inside the railway environment. Signalling and telecommunication apparatus mounted in vehicles is covered by EN 50121-3-2:2016, signalling and telecommunication apparatus installed inside the substation and connected to substation equipment is covered by EN 50121-5:2016.

This European Standard specifies limits for emission and immunity and provides performance criteria for signalling and telecommunications (S&T) apparatus (including power supply systems belonging to S&T) which may interfere with other apparatus inside the railway environment, or increase the total emissions for the railway environment and so risk causing Electro-Magnetic Interference (EMI) to apparatus outside the railway system.

The requirements specified in this standard apply for:

— vital equipment such as interlocking or command and control;

— apparatus inside the 3 m zone;

— ports of apparatus inside the 10 m zone with connection inside the 3 m zone;

— ports of apparatus inside the 10 m zone with cable length > 30 m.

Other apparatus not covered by at least one of these given cases should be in compliance with EN 61000-6-2.

If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g. transponder systems), then the radiated emission requirement in this standard are not intended to be applicable to the intentional transmission from a radio-transmitter as defined by the ITU.

Immunity limits do not apply in the exclusion bands as defined in the corresponding EMC related standard for radio equipment.

The standard does not specify basic personal safety requirements for apparatus such as protection against electric shock, unsafe operation, insulation co-ordination and related dielectric tests. The requirements were developed for and are applicable to this set of apparatus when operating under normal conditions. Fault conditions of the apparatus have not been taken into account.

The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified.

For products in the scope of EN 61000-3-2, EN 61000-3-3, EN 61000-3-11 or EN 61000-3-12 the requirements of those standards also apply.

These specific provisions are to be used in conjunction with the general provisions in EN 50121-1:2016.

The immunity and emission levels do not of themselves guarantee that the integration of apparatus will necessarily be satisfactory. The standard cannot cover all the possible configurations of the apparatus, but the test levels are sufficient to achieve satisfactory EMC in the majority of cases.


Edition : 17
File Size : 1 file , 850 KB
Number of Pages : 20
Published : 05/01/2017

History

CEI EN 50121-4
Published Date: 04/01/2018
Applicazioni ferroviarie, tranviarie, filoviarie e metropolitane - Compatibilità elettromagnetica Parte 4: Emissione ed immunità delle apparecchiature di segnalamento e telecomunicazioni
12.00 €
CEI EN 50121-4
Published Date: 05/01/2017
Railway applications - Electromagnetic compatibility Part 4: Emission and immunity of the signalling and telecommunications apparatus
11.70 €
CEI EN 50121-4
Published Date: 07/01/2016
Railway applications - Electromagnetic compatibility Part 4: Emission and immunity of the signalling and telecommunications apparatus
11.10 €
CEI EN 50121-4
Published Date: 10/01/2015
Railway applications - Electromagnetic compatibility Part 4: Emission and immunity of the signalling and telecommunications apparatus
11.10 €

Related products

CEI EN 61029-2-10
Published Date: 11/01/2010
Safety of transportable motor-operated electric tools Part 2: Particular requirements for cutting-off grinders
22.50 €
CEI UNI EN ISO 80369-1
Published Date: 03/01/2019
Small bore connectors for liquids and gases in healthcare applications - Part 1: General requirements
25.50 €
CEI EN 60855
Published Date: 12/01/1997
Insulating foam-filled tubes and solid rods for live working
22.20 €
CEI EN 50411-3-6
Published Date: 12/01/2022
Fibre management systems and protective housings to be used in optical fibre communication systems - Product specifications Part 3-6: Multi-mode mechanical fibre splice
13.50 €

Best-Selling Products

DOXPUB 02-0001-SOP
Published Date: 08/01/2007
Recovery of Cryopreserved Cells
DOXPUB 02-0002-SOP
Published Date: 08/01/2007
Removal of Adherent Cells from Tissue Culture Flasks Using Trypsin/EDTA Solution
4.20 €
DOXPUB 02-0003-SOP
Published Date: 08/01/2007
Assembly, Standardization, Sterilization and Inoculation of the Cell-Pharm Hollow Fiber Bioreactor for Antibody Production
20.70 €
DOXPUB 02-0006-SOP-1.0
Published Date: 11/01/2004
Concentration of Bulk Antibody
60.00 €
DOXPUB 02-0006-SOP
Published Date: 08/01/2007
Concentration of Bulk Antibody
14.70 €
DOXPUB 02-0007-SOP
Published Date: 08/01/2007
Cell Culture Fluid Waste Disposal
5.70 €