Description:

Solderless connections Part 5: Press-in connections - General requirements, test methods and practical guidance

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$48.3
Need Help?

Scope and object

This part of IEC 60352 is applicable to solderless press-in connections for use in telecommunication equipment and in electronic devices employing similar techniques.

The press-in connection consists of a termination having a suitable press-in zone which is inserted into a plated-through hole of a double-sided or multilayer printed board.

Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions.

The object of this part of IEC 60352 is to determine the suitability of press-in connections under mechanical, electrical and atmospheric conditions as specified by the manufacturer of the press-in termination and to provide a means of comparing test results when the tools used to make the connections are of different designs or manufacture.


Edition : 13
File Size : 1 file , 1 MB
Number of Pages : 40
Published : 02/01/2013

History

CEI EN IEC 60352-5
Published Date: 05/01/2021
Solderless connections Part 5: Press-in connections - General requirements, test methods and practical guidance
$25.5
CEI EN 60352-5
Published Date: 02/01/2013
Solderless connections Part 5: Press-in connections - General requirements, test methods and practical guidance
$48.3

Related products

CEI EN 62056-61
Published Date: 08/01/2007
Electricity metering - Data exchange for meter reading, tariff and load control - Part 61: Object identification system (OBIS)
$33.3
CEI EN 61000-3-3
Published Date: 07/01/2014
Electromagnetic compatibility (EMC) Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
$58.2
CEI EN 50564
Published Date: 01/01/2013
Electrical and electronic household and office equipment - Measurement of low power consumption
$62.7

Best-Selling Products