CEI EN 60534-8-2 PDF

CEI EN 60534-8-2 PDF

Name:
CEI EN 60534-8-2 PDF

Published Date:
07/01/2012

Status:
[ Active ]

Description:

Industrial-process control valves Part 8-2: Noise considerations - Laboratory measurement of noise generated by hydrodynamic flow through control valves

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$30.6
Need Help?

This part of IEC 60534-8 includes the method for measuring the sound pressure level due to liquid flow through a control valve and the method for determining the characteristic increase of noise due to the onset of cavitation. It also defines the equipment, methods and procedures for the laboratory measurement of the airborne sound needed to determine these characteristics.

Two methods are provided for testing the noise generating characteristics of control valves.

The first is a uniform method of measuring the radiated noise from the valve and the associated test piping including fixed flow restrictions through which the test fluid (water) is passing (see Note 1). The noise criteria are expressed by determining the sound pressure level of the valve under consideration.

The second is a procedure for measuring the sound pressure levels within pipe systems upstream and downstream of the valve under fixed operating conditions. Since inaccuracies due to the pipe transmission are eliminated, this method shall be preferred for evaluation of the acoustical characteristic of valves.

The noise characteristics to be determined are useful:

a) to determine acoustical characteristics of valves and valve assemblies and the characteristic pressure ratio factor xFz of a control valve;

b) to predict valve noise for given process conditions;

c) to compare the performance of different valves and various measuring results;

d) to plan measures for increasing service life and noise abatement;

e) to determine possible adverse effects on ultra-sonic flow meter measurements;

f) to enable proper sizing of sound absorbers.

NOTE 1 Test fluids other than water or valves without downstream piping are not within the scope of this section of IEC 60534-8.

NOTE 2 The factor xFz is used in a noise prediction method which is covered in IEC 60534-8-4.


Edition : 12
File Size : 1 file , 1 MB
Number of Pages : 30
Published : 07/01/2012

History


Related products

CEI EN 60335-2-42/A11
Published Date: 11/01/2012
Household and similar electrical appliances - Safety Part 2: Particular requirements for commercial electric forced convection ovens, steam cookers and steam-convection ovens
$5.4
CEI EN 60440
Published Date: 10/01/2013
Method of measurement of non-linearity in resistors
$20.4
CEI EN IEC 60751
Published Date: 10/01/2022
Industrial platinum resistance thermometers and platinum temperature sensors
$19.2

Best-Selling Products

NIRMA CM 1.0-2007
Published Date: 01/01/2000
American National Standard for Guidelines for Configuration Management of Nuclear Facilities